Instructions / Assembly

Step 2: For safety purposes, pre-drilled mounting
holes are provided through the back of the hood. For
a more secure installation, use as many mounting
holes as needed to secure the unit from the inside of
hood.
Step 3: Use a 8" diameter (size may vary) venting
pipe (follow building codes in your area) to connect
the exhaust on the hood to the ductwork above. Use
HVAC foil tape / duct tape to make all joints secure
and air tight.
SAFETY WARNING: Risk of electrical shock.
This range hood must be properly grounded. Make
sure this is done by qualified electrician in accord-
ance with all applicable national and local electrical
codes. Before connecting wires, switch power off to
prevent power from being switched on accidentally.
Step 4: Connect the range hood to a designated
standard outlet or cut off the plug and connect three
wires (black, white and green) to house wires and
cap with wire connectors. Connect according to col-
ors (i.e. black to black, white to white, and green to
green.) (If applicable).
Step 5: Store excess wires in the wiring box.
Step 6: Place oil tray into recess support near
the rear of the hood. Refer to Figure 6.
Step 7: To install baffle filters, refer to Figure 7
for placement.
1. Angle baffle filter toward the back of hood.
2. Push baffle filter up until almost leveled.
3. Slide iforward into recess behind the front of the
hood.
4. Lower the baffle filter.
5. Slide back until it fits into resting position.
Step 8: Repeat Step 7 to install all remaining baf-
fle filters.
Step 9: Turn power ON with Control Panel.
Check all lights and fan operations.
Step 10: Make sure to leave this installation
guide for the homeowner if you are a contractor.
AKDY Under Mount Range Hood Installation