User's Manual

Category:
External
Product/Project:
INSTALLATION
Page:
7 (12)
Subject:
INSTALLATION MANUAL SESAM 6099 TRANSMITTER
Document ID:
939045-000
Date:
2008-01-18
Written by:
Henrik Ring
Checked by:
Anders Modig
Approved by:
Henrik Ring
Version:
A1
ÅKERSTRÖMS BJÖRBO AB, SE-780 45 BJÖRBO, Sweden
Phone +46 241 25 000, Fax +46 241 232 90
Vat No SE556153982501 Registrated office BJÖRBO
www.akerstroms.se
6. Sesam 6099 Transmitter Operation
Use the numeric keys to change the display value.
The B7 button increments the display value with 1.
The B8 button resets the the display value to 0.
Press button B1-B6 to send a function.
The transmitter only transmits when a function key is pressed.
6.1. Low battery warning
The Sesam 6099 monitors the battery voltage continuously. Lo baT is displayed if the battery
voltage is to low (<6.5V). The battery voltage is displayed during warning and when replacing the
battery.
6.2. Battery replacement
The battery is accessed by removing the screws on the back of the transmitter with a PH1
screwdriver.
Use 9V alkaline batteries for replacement. For cold environments, a 9V lithium based battery is
recommended.
Note that the screws shall be tightened with 1 Nm torque.