7. Sesam 6099 Transmitter Configuration Menu
The transmitter has several parameters that can be configured using the keypad. To enter the
transmitter configuration menu, press and hold down the B7 and the B8 key simultaneously until
the display shows CF9 .
From the configuration menu the user can view/change up to 10 different parameters by pressing
the corresponding numeric key. To view the current setting of a parameter, press the corresponding
key (0-9) and wait for 2 seconds.
To change a parameter value, press the corresponding parameter button a second time. The display
will show a prompt ___ when a new value can be entered. When setting option 3 (program
mode) and 4 (LED control), only one of the fixed alternatives can be selected.
The display will show Err if an incorrect/invalid value is entered.
If no button is pressed for 10 seconds while in the configuration menu, the unit will return to normal
operation without saving any of the new parameters.
Press the store button B8 to save the new parameter setting. The display will show Sto to
confirm a successful store.
1. Area Code Id1 (0-255) Id1 (default - id1=0)
All transmitters in an area must have the same area code setting to interoperate. The area code
identity consists of two parts, Id1 and Id2, each value is in the range 0-255. Only transmitters with
identical id1, id2 and Customer Id setting can communicate with the same receiver.
2. Area Code Id2 (0-255) Id2 (default - id2=1)
See area code id1 above.
3. Program mode (OEM) (0..2) Pr9 (default - program=1)
Select one of the available OEM program options by pressing the ’3’ button repeatedly.
Program mode 0: Transmits the DIP-switch (SW2) value of the transmitter as the sub-ID.
Program mode 1: Transmits the serial number of the transmitter as the sub-ID.
4. LED control LED (default - on for 10 seconds)
This option selects the display illumination duration. Select one of the available options by pressing
the ’4’ button repeatedly.
t 5 The display will be lit for 5 seconds after a key is pressed.
t10 The display will be lit for 10 seconds after a key is pressed.
Off The display light will always be off. This option saves battery.
5. Battery voltage monitor bat
This option displays the current battery voltage.