Type: pre-polarized condenser microphone
Polar pattern: cardioid
Frequency range: 80 Hz to 20,000 Hz
Sensitivity: 35 mV/Pa (-46 dBV re 1 V/Pa)
Electrical Impedance at 1000 Hz: 200 ohms
Recommended load impedance: 2000 ohms
Max. SPL for 1% / 3% THD: 126 dB / 130 dB
Equivalent noise level: 22 dB(A) to IEC 60268-4
Supply voltage: B 29 L battery supply, MPA V L phantom
power adapter, or AKG WMS bodypack
transmitter
Current consumption: approx. 2 mA
Cable length/Connector: 1.5 m (5 ft.) / 3-pin mini XLR
Finish: matte black
Size (microphone only): length: 195 mm (7.7 in.);
max. dia.: 134 mm (5.3 in.)
Net weight (microphone l/cable): 26 g (0.9 oz.)
Shipping weight: 260 g (9.2 oz.)