Manual

6 Specifications
AKG C 520/C 520 L
21
Type: pre-polarized condenser microphone
Polar pattern: cardioid
Frequency range: 20 Hz to 20,000 Hz
Sensitivity: 7 mV/Pa -43 dBV re 1 V/Pa
Electrical Impedance at 1000 Hz: 200 ohms
Recommended load impedance: 2000 ohms
Max. SPL for 1% / 3% THD: 126 dB / 130 dB
Equivalent noise level: 33 dB (to DIN 45412)
Supply voltage: C 520: 9 to 52 V universal phantom power
C 520 L: 9 V battery supply through B 29 L
or bodypack transmitter, or 9 to 52 V uni-
versal phantom power through MPA V L
adapter
Current consumption: approx. 2 mA
Cable length/Connector: C 520: 3 m (10 ft.) / 3-pin male XLR
C 520 L: 1.5 m (5 ft.) / 3-pin mini XLR
Finish: matte black
Size: 130 mm (5.2 in.) in dia.
Net/shipping weight: C 520: 30 g/540 g (1.1/19.1 oz.)
C 520 L: 30 g/471 g (1.1/16.6 oz.)
This product conforms to the standards listed in the Declaration of Conformity.
To order a free copy of the Declaration of Conformity, visit http://www.akg.com or
contact sales@akg.com.
Frequency Response Polar Diagram