Installation Guide
Important: Do not apply pressure directly to the 
appliance manifold pipe when tightening supply 
connections. The manifold pipe should be held 
securely at the pressure regulator to prevent twisting. 
Hold the pressure regulator with a wrench during the 
tightening of the connection, or the manifold pipe may 
be twisted and split and cause a dangerous leak.
Note: Check all piping connections in the unit for leaks. 
Never use an open flame to check for gas leaks. Use a 
soap solution, 75% water, 25% dishwashing soap. It is 
possible for connections made at the factory to leak, 
due to vibration encountered in transportation. Make 
certain you have checked them all, and repair any 
connections that leak.
• The appliance and its individual shut-off valve must 
be disconnected from the gas supply piping system 
during any pressure testing of that system at test 
pressures in excess of 1/2 psig.
• The appliance must be isolated from the gas supply 
piping system by closing its individual manual shut-off 
valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 
1/2 psig.
Electrical Shock Hazard.
Do not use an extension cord.
Failure to follow these instructions can result in 
death, fire, or electrical shock.
• Any additions, changes, or conversions required for 
this appliance to meet the specific application needs 
must be performed by a qualified service technician 
in accordance with the manufacturer's instructions 
and all relevant codes and regulations. Failure to 
follow these instructions could result in serious injury 
or property damage. The qualified professional 
undertaking this work assumes responsibility for the 
conversion.
• DO NOT operate this appliance using a 2-prong 
adapter or an extension cord. If only a 2-prong wall 
receptacle is available, it is the consumer's personal 
responsibility to have it replaced with a properly 
grounded 3-prong wall receptacle installed by a 
qualified electrician.
• Severe shock or damage to the range may occur if 
the appliance is not installed by a qualified installer or 
electrician.
• This appliance requires a 120V/60Hz power supply. It 
is recommended to connect it to a 15-Amp or 20-Amp 
power supply.
• To reduce the possibility of gas leaks, apply Teflon tape 
or a thread compound approved for use with LP or 
natural gases to all threaded connections.
• Install a manual gas line shut-off valve in the gas line in 
an easily accessed location outside the range in the gas 
piping external to the appliance for the purpose of 
turning on or shutting off gas to the appliance.
• Install a male 1/2" (30- or 36-inch range top) or 3/4" 
(48-inch range top) flare union adapter to the 1/2" or 
3/4" NPT internal thread elbow at the inlet of the 
regulator. Use a wrench on the regulator fitting to avoid 
damage.
• Install a male 1/2" or 3/4" flare union adapter to the NPT 
internal thread of the manual shut-off valve, taking care 
to secure the shut-off valve to keep it from turning.
• Total Input Power is 14.1 kW (AN-2160), 20.8 kW 
(AN-2161), 27.5 kW (AN-2162), 3 A for range tops. Total 
Input Power is 23.4 kW (30" range), 30.2 kW (36" 
range), 41.1 kW (48" range), 5 A for ranges. A dedicated 
circuit protected by a minimum 15 to 20-amp time delay 
fuse or circuit breaker is required.
• For personal safety, it is essential that the appliance is 
properly grounded.
• The power supply must have the correct polarity. 
Reverse polarity can result in continuous sparking of the 
electrodes, even after flame ignition. If there is any 
uncertainty about the power supply's polarity or 
grounding, it should be checked by a qualified 
electrician.
GAS CONNECTIONS (All Units)
ELECTRICAL DANGER
GAS LINE SHUT-OFF VALVE
WARNINGS:
cooking appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-pronged receptacle.
plug.
Caution: label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
Important Safety Information
10