Installation Guide and Users Manual Questions, problems, missing parts? Before returning to the store, call NAUXUS Customer Service 8 a.m.-6 p.m.,EST, Monday-Friday 1-(832)941-6306 1-(909)858-6868 NAUXUS.COM IMPORTANT: Read and save these instructions.
Important Safety Notice Read all Instructions before Installing and operating this appliance • • • • • The installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. DO NOT attempt to install this appliance yourself.
Important Safety Notice Read all Instructions before Installing and operating this appliance • • • Clean ventilating fan frequently. Always use appropriate cookware and utensils size. Always use cookware appropriate for the size of the surface element. To reduce the risk of injury to persons in the event of a stove top grease fire: • • • SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn OFF the burner. BECAREFUL TO PREVENT BURNS.
Table of Contents INSTALLATION Tools needed....................................................3 Parts supplied...................................................4 Venting requirements.......................................5 Mount heights & clearance...........................5-6 Calculating vent system length.......................6 Venting methods...........................................7-8 Charcoal filter Installation...............................8 Electrical requirements..............................
Parts supplied: Range Hood M4 x 35mm QTY: 10 Baffle Filter Oil Tunnel Filter spacer 6" Round Adapter Page 4 3.25" x 10" Adapter 3.
Venting Requirements • • • • • • • Vent system must terminate to the outside (roof or side wall). Do not terminate the vent system in an attic or other enclosed area. Do not use 4” (10.2 cm) laundry-type wall caps. Use metal/aluminum vent only. Rigid metal/ aluminum vent is recommended. Do not use plastic vent. Always keep the duct clean to ensure proper airflow. Calculate the following figures before installation: 1. Distance from the floor to the ceiling. 2.
Height & Clearance (Continued) IMPORTANT: • A minimum of 6” round (standard for this range hood) must be used to maintain maximum airflow efficiency. • Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct. • Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions and caps. • ALWAYS, when possible, reduce the number or transitions and turns.
Venting Methods • • • This power pack range hood insert is factory set for venting through the roof or wall. Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed. Choose the required vent option. You can choose the TOP vent or the Rear vent. 1. Top Vent * 6" Round Adapter The Round Adapter is pre-installed for the top vent. You can use it directly. See Figure 1. *3.25" x 10" Adapter -Remove the pre-installed Round Adapter.
Venting Methods (Continued) Figure 3 Figure 4 Figure 5 Roof Cap Round Duct Round Elbow Power Pack Range Hood Insert Wall Cap 24” to 30” Above Cooking Surface Charcoal Filter Installation NOTE: 1.Remove grease filters from the hood. 2.Position the charcoal filters onto the side of the motor, aligning the mounting points, turn until it locks. average of 1 to 2 hours of daily cooking time). Available at your local resellers. Re-install grease filters. 3.
Electrical Requirements IMPORTANT: Observe all governing codes and ordinances. (Please consult with a qualified electrician for 220-Volt 50 Hz voltage) It is the customer’s responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/ NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91 - latest edition** and all local codes and ordinances.
Installation Excessive Weight INSTALL THE HOOD Due to excessive weight, two or more person is recommended for this step. Require two or more person to move and install this range hood. Spinal or other bodily injuries could occur if it is not followed. NOTE: DO NOT INSTALL THIS POWER PACK RANGE HOOD INSERT BEFORE RUNNING A TEST AND MAKE SURE THE UNIT IS IN GOOD CONDITION. MECHANICAL DAMAGE MIGHT HAVE OCCURRED DURING TRANSPORTATION. 1. Remove the decorative panel from the power pack range hood. 2.
Range Hood Operations 3 Speed Electronic Touch Control Power Power-Off Delay Decrease Value Blower Speed Indicator Light Increase Value Power-Off Delay Digital Timer Cleaning Reminder Indicator This range hood is designed to remove smoke, cooking vapors and odors from the cook top area. For best results, start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen.
Range Hood Operations (Continued) 3 Speed Electronic Touch Control Power Power-Off Delay Decrease Value Blower Speed Indicator • Light Increase Value Power-Off Delay Digital Timer Cleaning Reminder Indicator Controls: • Adjusting the timer function: • While the blower (motor) is not running, press and hold Decrease Value button over 3 seconds to enter timer mode. Adjust to desired period of delay off timer by pressing Increase Value or Decrease Value button (minimum 1 minute to maximum 9 minutes).
Product Dimension NX-E90-30 / NX-E90-36 Wiring Diagram Page 13
Troubleshooting 1. If the range hood does not operate after installation: • • Check if the range hood has been plugged in, make sure that all power has been turned back on and all electrical wiring are properly connected. Swap out light assembly to working ones to determine whether it is caused by defective bulbs. (See Replacing the light bulbs, page 17) 2. The range hood vibrates when the blower is on: • The range hood might not have been secured properly. 3.
Use and Care Information WARNING — TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
Maintenance SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating! For optimal operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will help preserve the appearance of the range hood. Cleaning Exterior surfaces: • Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g.
Maintenance (Continued) Replacing LED Light Fixture: • This range hood uses LED light fixture: 3W Max 12V LED • Make sure the range hood is unplugged or turn OFF breaker and the lights are cool to touch. • Place a flat-head screwdriver between light housing and hood body, gently pry up the light housing and search for the metal clip. • Apply force to the metal clip and pull out the light fixture. Disconnect the power cable and discard the old light fixture.
Disclaimer Carefully inspect all items for damages before accepting delivery. note any damages on the freight bill or express receipt. request name and signature of the carrier’s agent and keep copy to support your claim. Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with necessary forms for filing a claim.