Venting Methods
• This power pack range hood insert is factory set for venting through the roof or wall.
• NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or
•
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
garages. All exhaust must be ducted to the outside.
• Use metal/aluminum duct work only.
• Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.
• Use caulking to seal exterior wall or roof opening around the cap. See Figure 5.
•
Choose the required vent option. You can choose the TOP vent or the Rear vent.
1. Top Vent
* 6" Round Adapter
The Round Adapter is pre-installed for the top vent. You can use it directly. See Figure 1.
*3.25
"
x 10
"
Adapter
-Remove the pre-installed Round Adapter. Keep screws to attach Rectangular adapter and Rectangular
duct transition.
-Place Rectangular Adapter and Rectangular duct transition with screws. See Figure 2.
2. Rear Vent
*6” Round Adapter
-Remove the Rear Vent Cover. Keep screws to attach Round Adapter to the rear vent.
-Remove the pre-installed Adapter from the top vent.
-Sealing the top vent, remove the vent cover from the rear vent.
-Remove the four screws that secure the blower system. Hold the blower to keep it from dropping as you
remove screws. Keep screws to re-attach the blower. Slowly rotate the blower system to align with the
mounting holes at the back of the insert— secure the blower using four screws.
-Attached 6” Round Adapter to the rear vent using screws removed from the vent cover. See Figure 3.
*3.25
"
x 10
"
Adapter
-Remove the Rear Vent Cover. Keep screws to attach Rectangular adapter and Rectangular duct
transition to the rear vent.
-Remove the pre-installed Adapter from the top vent.
-Sealing the top vent, remove the vent cover from the rear vent.
-Remove the four screws that secure the blower system. Hold the blower to keep it from dropping as you
remove screws. Keep screws to re-attach the blower. Slowly rotate the blower system to align with the
mounting holes at the back of the insert— secure the blower using four screws.
-Attached is a 3.25
"
x 10
"
Adapter to the rear vent using screws removed from the cover. See Figure 4.
IMPORTANT:
Figure 1 Figure 2