Product Info
Table Of Contents
- 1.Product Overview
- 2.Change Log
- 3.Model Difference
- 4.Introduction to Configuration Menu
- 5.Access the Device
- 6.Language and Time Setting
- 7.Screen Display Configuration
- 8.Sound and Volume Configuration
- 9.Phone Book Configuration
- 10.Network Setting
- 11.Intercom Call Configuration
- 11.1.IP call & IP Call Configuration
- 11.2.SIP Call &SIP Call Configuration
- 11.3.SIP Account Registration
- 11.4.SIP Server Configuration
- 11.5.Outbound Proxy Server configuration
- 11.6.SIP Call Configuration
- 11.7.Device Local RTP configuration
- 11.8.Data Transmission Type Configuration
- 11.9.Call Setting
- 11.10. Intercom Call Configuration
- 11.11.SIP Hacking Protection
- 11.12.Emergency Call Setting
- 11.13.Multicast Configuration
- 11.14.Call Forwarding Setting
- 12.Intercom Message Setting
- 13.Audio& Video Codec Configuration for SIP Calls
- 14.Security
- 14.1.Monitor and Image
- 14.2.Alarm and Arming Configuration
- 14.2.1.Configure Alarm and Arming on the Device
- 14.2.2.Configure Alarm and Arming on the Web Interface
- 14.2.3.Configure Location-based Alarm on the device scree
- 14.2.4.Configure Location-based Alarm on the Web Interfac
- 14.2.5.Configure Alarm Text
- 14.2.6.Configure Arming mode
- 14.2.7.Alarm Action Configuration
- 14.2.8.Check Alarm Log
- 14.3.Screen Unlock Setting
- 14.4.Client Certificate Setting
- 14.5.Power Output Setting
- 15.Door Access Control Configuration
- 16.Device Integration with Third Party Device
- 17.Firmware Upgrade
- 18. Backup
- 19.Auto-provisioning
- 20.Call Log
- 21.Debug
- 22.Password Modification
- 23.System Reboot&Reset
- 24.Abbreviations
- 25.FAQ
- 26.Contact US
C313W Indoor Monitor Administrator Guide
AKUVOX SMART INTERCOM www.akuvox.com
79
15. Door Access Control Configuration
15.1.Relay Switch Setting
15.1.1. Local Relay Setting
Local relays in Akuvox indoor monitor can be used to trigger the door access
or Chime bell through local relay connector. You can do this configuration on
web interface Phone > Relay > Relay Setting > Local Relay.
Parameter set-up:
DTMF: Set the DTMF code for local relay.
Relay Interval: set the relay delay time after the relay is triggered.
Relay Type: set relay action type. There are two types of relay, chime bell
and open door. Chime Bell, when there is a call, the chime bell will ring.
Open door, when press the unlock icon, the local relay will be opened.
15.1.2. Remote Relay Switch Setting
You can use the unlock tab during the call to open the door on web Phone >
Relay > Relay Setting > Remote Relay interface. You are required to set up the
same DTMF code in the door phone and indoor monitor.