3.6.6. Wiegand
Using this feature to integrate with some wiegand access control.
E11R can be used as wiegand input or output.
Go to Intercom - Advanced to configure.
Wiegand Type: Support Wiegand 26 or 34. The different number
means different bits.
Wiegand Mode: Input or output. Typically, when users select input,
E11R will receive the data from wiegand port. We generally connect
the wiegand input device, such as the wiegand card reader. Or
E11R can be used as output, it is generally used to connect the
third-party access control, and E11Rsends the data as wiegand
signal, and then transfer to the access control module.
3.7. Reboot
Go to Upgrade - Basic, users can reboot the phone.
Figure 3.7 Reboot
Figure 3.6.6 Wiegand