18.3. OSDP Setting
If you choose OSDP integration mode, you can not only check for OSDP
status but also obtain the authentication from the third-party devices for
various applications such as door access etc. To configure the configuration
on web Device > RS485 > OSDP Advance Setting interface.
Parameter Set-up:
Connect Status: indicate OSDP based communication status.
Send by: select in what way you want to send out the card number
among three options: OSDP, Wiegand and None. if you select OSDP then
the card number will be sent out to the third party devices via RS485. if
you select Wiegand then the card number will be sent out via wiegand. If
you select None then the card number will not be sent out but retained in
NO.
Integration Mode
Description
1
None
If you select None then the RS485
integration will be disabled.
2
OSDP
If you Select OSDP Mode, then the
integration communication between the
E16C door phone and the third party device is
via OSDP protocol. You are required to check
for the device integration protocol and make
sure if that they use the same integration
protocol.