Product Info

Table Of Contents
Single TenantDoor Phone
AKUVOX SMART INTERCOMwww.akuvox.com 70
( HTTP://:@IP address>/state.xml?relayState=2)
b. If you have already filled in the IP address above, fill in the omitted
HTTP command, eg. state.xml?relayState=2.
Web Relay Key:it can be null orenter the configured DTMF code, when the
door is unlock via DTMF code, the action command will be sent to the web
relay automatically.
Web Relay Extension: it can be null or enter the relay extension
information, which can be a SIP Account user name of an intercom device
such as an indoor monitor, so that the specific action command will be sent
when unlock is performed on the intercom device, while this setting is
optional.
13.3. Power Output Control
R20A can serve as a power supplyfor the external relays.You can set it up on
the web Intercom > Relay > 12V Power Output.