Single TenantDoor Phone
AKUVOX SMART INTERCOMwww.akuvox.com 85
Session Check: enable it to protect data transmission security.
UserName: enter the user name of the device web interface, for example,
“Admin”.
Password: enter the password for the HTTP command. For example:
“12345”.
Please refer to the following example:
http://192.168.35.127/fcgi/do?action=OpenDoor&UserName=admin&Passwor
d=12345&DoorNum=1
15.7. Configure Exit Button for Door Unlock
Note:
DoorNum
in the HTTP command above refers to the relay number #1
to be triggered for the door access.