AKUVOX SMART INTERCOMwww.akuvox.com 86
When you need to open the door from inside using the Exit button installed by
the door, you can configure the door phone Input to trigger the relay for the
door access on web Intercom > Input interface.
Parameter set-up:
Enabled:enable the function if needed.
Trigger Electrical Level: select the trigger electrical level options between
Highand Low” according to the actual operation on the exit button.
Action To Execute: select the method to carry out the action among four
options: FTP, Email, HTTP, TFTP.