Product Info

Table Of Contents
Single Tenant Door Phone
AKUVOX SMART INTERCOM www.akuvox.com
98
authentication.
Password: enter the password of the lift controller for the authentication.
Floor NO. Parameter: enter the Floor number parameter provided by
Akuvox. The default parameter string is $floor”. You can define your own
parameter string if needed.
URL To Trigger Specific Floor: enter the Akuvox life control URL for
triggering a specific floor. The URL is /cdor.cgi?open=0&door=$floor,
but the string “$floor at the end must be identical with the parameter
string you defined.
URL To Trigger All Floors: enter the Akuvox URL for triggering all floors.
URL To Close All Floors: enter the Akuvox URL used for closing all floors.
23.6.ZKT Lift Controller
You are required to configure ZKteco lift controller before you can connect
the door phone to the lift controller. You can navigate to Lift Control > Akuvox
EC32 & ZKT Advance Setting.
Parameter Set-up:
Server IP: enter the IP address of the Akuvox EC32 controller server.
Port: enter the port of Akuvox EC32 controller server.