Product Info

Table Of Contents
Multi Tenant Door Phone Administrator Guide
AKUVOX SMART INTERCOM www.akuvox.com
export the PIN code files in batch if needed.
Parameter Set-up:
PKey DoorNum: select relay switches (Door A; Door B; Door C ) to be
triggered by the PIN Code you created for the door access.
PKey Day: select the day (s) on which private PIN code can be valid for
the door access. For example, you select Check All if you want PIN code
to be valid through out the week, or you can select specific day on which
the PIN code can be valid.
PKey Time: select the time span during a day you want the private PIN
code to be valid for the door access.
PKey WebRelay: it will trigger the webrelay action when using the
corresponding PIN code. The default is 0, the other number corresponds
to the related action ID.
PKey Floor: the floor number with the PIN code for a resident. So you can
enter the PIN code to access the corresponding floor. It need to be used
with lift control feature.
PKey Name: enter the Private PIN code name for identification, for
example, you can enter user name as PIN code name indicating the PIN
code ownership.
PKey Code: enter the PIN code number to your preference.