Product Info

Table Of Contents
Multi Tenant Door Phone Administrator Guide
AKUVOX SMART INTERCOM www.akuvox.com
Wiegand Output Order: Set the wiegand output sequence, the default is
Normal, the input is in the positive sequence, and if Reversed is selected,
the reverse input, such as the external wiegand swipe card, the card
number is 12345678, the positive input is 12345678, and the reverse
input is 78563412.
Wiegand Output CRC: it is used for parity check when Wiegand output
data, the default is OFF. When set to On, Wiegand will perform parity
checking when outputting data; when set to OFF, Wiegand will not
perform parity checking when outputting data.
23.2.Integration via HTTP API
HTTP API is designed to achieve an network-based integration between the
third party device with the Akuvox intercom device. You can configure the
HTTP API function on the web Intercom > HTTP API interface for the
integration.