Password: enter the password when Basic and “Digest authorization
mode is selected. The default user name is Admin”.
1st IP-5th IP: enter the IP address of the third party devices when the
“WhiteList” authorization is selected for the integration.
25.3.Power Output Control
X912S can serve as a power supply for the external relays. Path: Intercom >
Access Control >>12V Power Output.
Parameter Set-up:
Relay ID: select the relay to be powered by X912S
12V Power Output: select Disabled to disable the power output function;
select Always to enable the access controller to provide continuous
power to the third party device. Select Triggered By Open Relay if you
want the E18 to provide power to the third party device via 12 output and
GND interface during the timeout when the status of relays is shifted
from low to high.
Time Out (Sec): select the power supply time duration after the relay is
triggered. Three options: 3, 5, 10. It is 3 seconds by default. The power
output is 12V, and the maximum output amperage is 0.8A.