Web Relay Action: enter the specific web relay action command provided
by the web manufacturer for different actions by the web relay.
Web Relay Key: enter the configured DTMF code, when the door is
unlocked via DTMF code, the action command will be sent to the web
relay automatically.
Web Relay Extension: enter the relay extension information, which can be
a SIP Account user name of an intercom device such as an indoor
monitor, so that the specific action command will be sent when unlock is
performed on the intercom device, while this setting is optional. And
please refer to the example below:
http://admin:admin@192.168.1.2/state.xml?relayState=2.
After the web relay is set up, you can configure the specific web relay to be
triggered based on the relay location for the door access. To do so, navigate
to Directory > User, click + Add”, then scroll down to Access Setting. And
select the specific web relay action you need.
15.2.2. Configure Security Relay
Akuvox security relay is connected to the door lock via Akuvox door phone. It
is installed in side of the door and serves as extra protection against the
forced door unlock through tampering of the door phone. The security relay
is applied in applications requiring a higher level of security. To set up the
security relay, navigate to Access Control > Relay > Security Relay.