Instructions

Table Of Contents
en
Product description
14 DRAIN 10000-15000 | INOX DRAIN 20000 HD
Waste water
Dirty water having a max. suspended matter
proportion of 5 % and a grain size of max. 30
mm* diameter.
Any use not in accordance with this designated
use shall be regarded as misuse.
* 38 mm Drain 20000 HD
Possible misuse
The immersion pump must not be used conti-
nuously. They are not suitable for conveying:
Drinking water
Salt water
Foodstuffs
Aggressive media, chemicals
Corrosive, flammable, explosive or fuming
fluids
Fluids that are hotter than 35 °C
Water containing sand and abrasive fluids
SCOPE OF DELIVERY
Thermal protection
The unit is fitted with a thermal protection switch
which switches the motor off in the event of over-
heating. The pump switches on again automati-
cally after a cooling down period of approx. 15 -
20 minutes.
Operate the unit only if the immersion pump is fully
immersed.
SAFETY INSTRUCTIONS
CAUTION!
Risk of injury!
Use the machine and the extension ca-
ble only in perfect working order. Dama-
ged equipment may not be operated.
Do not disable safety and protective de-
vices!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
Electrical safety
CAUTION!
Danger when touching voltage con-
ducting parts!
Disconnect the plug from the mains if the
extension cable is damaged or severed!
We recommend connecting a RCD (re-
sidual current operated device) having a
nominal residual current of < 30 mA.
The pump may not be operated while people
are in the pool or pond.
The house mains voltage must agree with the
details quoted in the technical data, do not
use any other supply voltage.
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702. Protection
must be provided by a 10 A line protection
switch and a RCCD (residual current opera-
ted device) having a nominal residual current
of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
2
. Cable drums should always be unrolled
completely.
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Mounting the pressure line
see Fig. A,D and G
1. Screw the connection elbow (7) into the pump
outlet.
2. Screw the combination nipple (8) into the con-
nection elbow.
3. Fix a hose to the combination nipple.
ADVICE
The combination nipple can be trim-
med to suit the selected hose con-
nection. Use the largest possible
hose diameter.