6. Remove motor canopy.
Capacitor voltage can be dangerous.
Before proceeding, short the capacitor terminals
together with a screwdriver that has an insulated
handle.
Being careful not to touch capacitor terminals,
loosen capacitor clamp and move capacitor to one
side.
7. Hold shaft with 7/16" open-end wrench on motor
shaft flats.
NOTICE: On models with impeller screw, remove
impeller screw (left hand thread - turn clockwise)
and gasket before removing impeller. Inspect
gasket for damage, cracks, etc. Replace if
damaged.
8. Unscrew impeller from shaft (turn counterclockwise
when facing it).
9. Remove four screws holding seal plate to motor.
10. Place seal plate face down on flat surface and tap out
ceramic seat (Figure 8).
11. Clean seal cavity in seal plate and clean motor
shaft.
Pump Reassembly/Installing New Seal
1. Ceramic seat must be clean and free of dirt, grease,
dust, etc. Wet outer edge of O-Ring with small
amount of liquid detergent; press ceramic seat into
seal plate cavity firmly and squarely with finger
pressure (Figure 9).
2. If ceramic seat will not locate properly, remove it,
place face up on bench and reclean cavity. Ceramic
seat should now locate.
3. If seat still will not locate properly, place a
cardboard washer over the polished face and use a
piece of 3/4" (19mm) standard pipe for pressing
purposes.
NOTICE: Be sure not to scratch or mar polished
surface or seal will leak.
4. Remount seal plate on motor. Tighten bolts to 60-80
inch-lbs. (69-92 kg/cm) torque.
5. Apply a small amount of liquid detergent to inside
diameter of rotating half of seal.
6. Slide rotating seal member, polished face last, over
threaded shaft end and shaft shoulder until rubber
drive ring hits shaft shoulder.
NOTICE: Be sure not to nick or scratch polished
seal face; seal will leak if face is damaged.
7. Screw impeller onto shaft (clockwise); this will
automatically locate seal in seal plate.
NOTICE: On models with impeller screw: install
impeller gasket and lock screw (left-hand thread –
turn counterclockwise).
8. Mount diffuser on seal plate; tighten screws to 10-
14 inch-lbs. (11.5-16.1 cent.-kg.) torque.
9. Assemble motor and seal plate to volute; be sure
clamp is properly seated. NOTICE: Clamp knob can
be located in any position around volute; if it is
moved after assembly, tighten knob while tapping
around clamp to assist sealing. Do not move clamp
while pump is full of water.
Hazardous pressure. Release all pressure
from pump and piping system before working on pump
or attempting to adjust or remove clamp. Clamp may
blow off of pump if adjusted under pressure.
10. Reinstall pump base mounting bolts (if used) and
prime pump according to instructions on Page 9.