within 500 mm of painted eaves, then an aluminum shield at least 1000
mmlongshouldbettedtotheundersideofthegutterorpaintedsur-
face.
The terminal should be tted less than 2 meters above a surface to
which people have access.
In certain weather conditions a terminal may steam and sitting where
this could cause a nuisance should be avoided.
Take care to ensure that combustion products do not enter ventilated
roof voids.
Whereelongationoftheuepipeisanecessary,onlyoriginalextension
pipe and elbow must be used.
Theuesystemcanbeinstalledfrominsidetheroomwithoutaccess
to the external wall and regardless of the wall thickness providing that a
suitablewalllineristted.
ATTENTION!Flueterminalmustbettedwith3%downwardinclination
to prevent rain leaking in to the boiler.