Technical data
49
4.4 ELECTRICAL
Cable adjusting and cable type between boiler and main supply, should
obey all related local and national regulations.
Properties of the Harmony_D PCB are as follows;
Supplyvoltage 230Vac+10%/-15%
Supplyvoltagefrequency 50Hz+/-5%
Max power uptake 8VA
Maximumpermittedhumidity max90%@40°Cnocondensing
Class of protection against electric shocks cl.II
Working environment clean
Protection class IP00
Printed circuit material FR4
Protective fuse (line) 1 x 3,15AF (5x20mm)
The data mentioned above – if no different data is indicated – is referred
to following standard conditions:
• Temperature:25°C
• Powersupply:230Vac
1) It must be possible to completely isolate the appliance electrically.
2) The following connection alternatives must be used: A 3 amp fused
three-pin plug and unswitched shuttered socket outlet or a double
pole isolator with a contact separation of 3 mm in all poles and sup-
plying the appliance and controls only.
3) The appliance must be earthed.
4) Use the original mains cable provided with the boiler. If there is dam-
age, it should be replaced with an original spare by authorized Alarko
Carrier services.