ADC-620T Module| Installation Guide
--
7
Telephone Line Monitoring
001 - 002
--
Panel/Receiver Communication
Paths
001 - 004
--
Phone Number Programming
001
1 - 2
Maintenance Events/Restores Call
Directions
002
1 - 2
Test Transmissions Call Directions
000
--
System Account Code
001 - 008
--
Partition Account Codes
001
1 - 2
Alarm/Restore Partition Call
Directions
002
1 - 2
Tampers/Restore Partition Call
Directions
003
1 - 2
Openings/Closing Partition Call
Directions
001
--
Communicator Formats
--
2
Communicator Backup Options
Zone Attributes
Subsections [001] through [128] of section [002] control the attributes for
each zone. Option [5] enables or disables Force Arming. If this option is set to
OFF, the system cannot be armed if the zone is opened.
Notifications
The following panel settings may alter the behavior of customer
notifications:
Section
Option
Description
015
4
If this option is ON, keyfob arming notifications will
not be associated with a specific user.
016
8
If this option is OFF, notifications will not be
available for keypad tampers. Set to ON to enable
tamper notifications.
Not Supported
The following panel settings are either handled automatically or not
supported and thus any changes to them will be ignored:
Section(s)
Subsection(s)
Option(s)
Description
324-348
All
Custom Reporting
Codes
377
001
Tampers/Restores
Max number of
transmissions
609-611
All
Reporting Codes
Panel Settings Automatically Change
Some panel settings are changed automatically when the ADC-620T Module
is
connected to the control panel. These settings should not be altered. They
are:
Section
Subsection
Option
Value
Description
015
--
6
OFF
Master Code Not
Changeable must be OFF
to ensure module
communicates the
correct master code.
017
--
6
OFF
Daylights Saving Time
must be disabled to
ensure panel time is
accurate.
024
--
5
OFF
Realtime Clock must be
disabled to ensure panel
time is accurate.
041
--
--
00
User Access Codes must
be 4-digits.
377
001
Maintena
nce
Troubles/
Restores
014
Max number of
transmissions should be
14.
377
002
AC
Failure
Communi
cation
Delay
Random
value
between
001 and
030
AC Failure
Communication Delay
should be set between
001 and 030 to ensure
notifications for power
failures are received.
377
002
Wireless
Zone Low
Battery
Transmis
sion
Delay
001
Wireless Device Low
Battery Transmission
Delay should be set to
001 to ensure
notifications for low
batteries are received.
380
--
1
ON
Communications must be
enabled so the Module
can communicate with
the panel.
380
--
2
OFF
System should transmit
alarm restores
immediately when the
zone is restored.
380
--
5
OFF
System should not
attempt to communicate
through all available
receivers at the same
time.
382
--
5
ON
Communications must be
enabled so the Module
can communicate with
the panel.
382
--
6
OFF
AC Failure Transmission
Delay should be in
minutes.
Clock: The ADC-620T Module sets the panel clock when it connects to
Alarm.com
and then updates it every 18 hours. It is important to select the correct panel
time zone on the Alarm.com website, or the panel time will not be accurate.
If a system is powered up before the customer account has been created,
the time zone will default to Eastern Time.
Troubleshooting: Module Status Information
Module status information for verifying and troubleshooting module
connection status or errors can be found through the Interactive Services
menus on Neo. Go to the ‘Interactive Services’ → ‘Module Status’ menu.
See Table 1 below for potential module states.
Table 1: ADC-620T Module Statuses
Idle
Most common state
Roaming
Roaming on partner network
SIM Missing
The SIM card is missing
PowerSave Mode
AC Power is Down
Registering…
The module is trying to register on the
cellular network