User's Manual

13
Zone Wiring (Zone 1 -16)
The 16 zones can be wired by supervising NC (normally close) or NO (normally open)
devices, e.g. PIR sensor, door contact, smoke detector, water sensor, fire sensor, CO
sensor, gas detector, heat detector, and glass break detector, etc.
Wire gauge: Minimum 20 AWG, maximum 18 AWG. Do not use shielded wire.
The hardwired zones support Single-End-of-Line (SEOL),Double-End-of-Line (DEOL)loop
configuration, with a value from 1K, 2.2K, 3.74K, 4.7K, 5.6K, 6.8K, 8.2K,10K ohms, and
Triple end-of-line (TEOL) loop (only for 4.7K, 6.8K, 12K). Please install the resistor(s) at the
end of each zone loop far away from the Control Panel. The Panel will detect if the circuit is
secure, open, or short.
For an NO loop, please have an EOL resister in parallel (across) the loop.
For an NC loop, please have an EOL resistor in series with the loop.
If a zone wiring method is changed, be sure to turn the system power off and back on again
to avoid triggering the alarm.
Please refer to the following diagrams of loop 1 to 10 for wiring examples.
NO/NC Wiring
The panel can detect alarm for corresponding NO or NC devices via the open, secure or
shorted circuits.
<NOTE>
There is no EOL resistor in loop 1 and loop 2
1. 2.