Installation Instructions

Page 4
DOCAES200 REV. B 11/13
MECHANICAL RATINGS
Static Strength
Dynamic Strength
Endurance
1000 lbs - force
-10°C to +40°C, 14°F to +104°F
70 ft - lbs - force
500 000 cycles
This electric strike operates on a 12 through 24 VAC or VDC.
CAUTION!
Before connecting any device at the installation site, verify input voltage and current using a multimeter.
Many power supplies and transformers operate at higher levels than listed. Any input voltage exeeding 10% of solenoid
rating may cause severe damage to the unit and will void the warranty.
GENERAL INFORMATION
WIRING
FAIL SAFE/FAIL SECURE SELECTION
ELECTRICAL RATINGS Continuous Duty Operating Temperature
FOR SOLENOID
12 VAC 24 VAC 12 VDC 24 VDC
Resistance in Ohms 58 230
Watts Seated 2.5 1.68 1.56 1.68
Amps Seated .2 .07 .13 .07
AES-200 (fail secure)
Solenoids are rated at +/- 1 0% indic ated value
SPECIFICATIONS
58 230
Limited Lifetime Warranty
WIRING DIAGRAMS AND GENERAL SPECIFICATIONS
Check voltage!
c ncno
24 V
1 A
12 V/0.2 A
24 V/0.1 A
AC/DCAC/DC
Using a multimeter, confirm that you have the correct
output voltage at the power supply.
Then, using a multimeter, confirm that you have the
correct input voltage at the strike.
+/- doesn't matter!
Latch monitoring outputs.
Fail safe
Fail secure