Installation Guide
2 
MOUNTING AND INSTALLATION 
For factory prepped doors, use dimensions shown. Di-
mensions are referenced from center of 1¼" cylinder hole.  
The Adams Rite
®
 lock determines the backset. 
When mounting the new Adams Rite® locks: 
• Do not install the outside cylinder -- this trim replaces it; 
• Do not install the faceplate (access to the cylinder set 
screw in the lock is required during mounting and instal-
lation). 
Mechanical Override Cylinder Cams 
The DL1200 and DL/PDL1300 trim requires the use of an 
oval  Alarm Lock cam (supplied with cylinder). For other 
manufacturers, please see the charts below. 
Cylinder Collars: 
The DL1200 and DL/PDL1300 can use a 1-1/8" & 1¼" mor-
tise cylinder without the use of a collar (1¼" requires two 
plastic spacers, supplied). For cylinders longer than 1¼" a 
collar is required. 
Order collars from an Alarm Lock distributor. 
Template (use WI1459) 
Backset is determined by 
the Adams Rite lock 
Corbin-Russwin  HW1344 
Marks  HW1346 
Arrow  HW1348 
Schlage  HW1349 
Cams for Standard Mortise Cylinders  
Sargent  HW1348 
Cams for IC Mortise Cylinders  
Best*  HW1343 
Corbin-Russwin  HW1345 
Medeco  HW1347 
Schlage  HW1350 
Yale  HW1351 
*Will be supplied together with Best IC Housing (HW1352) 
Cylinder Length  Collar P/N 
1-3/8  HW1331 
1-½  HW1342 
Cam for Mechanical Override Cylinder 