ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ EagleSmart ES2400, ES2403, ES4800, ES6000 USER'S MANUAL V2.3 – August 2006 www.eagletronicchargers.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ INDEX · 1. SAFETY INSTRUCTIONS AND WARNINGS............................................. 3 · GENERAL.................................................................................................................... 3 · SHOCK PREVENTION..............................................................................
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ 1. SAFETY INSTRUCTIONS AND WARNINGS Before to start using your EagleSmart battery charger, please take the time to read these instructions carefully. The owner’s manual is an important part of the charger. It’s recommended to keep it in good condition for the lifetime of the charger.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ SERVICE AND MAINTENANCE – Shut OFF all power at the disconnect switch or line breaker BEFORE inspecting, adjusting, or servicing the equipment. Lock switch OPEN (or remove line fuses) so that the power cannot be turned ON accidentally. Disconnect power to equipment if it is to be left unattended or out of service.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ 2. DESCRIPTION OF THE CHARGER EagleSmart battery chargers have been designed to charge Lead-Acid batteries. These units convert the AC input to a DC output at the correct voltage. The charge curve is Wa, with programmable finishing charge time and automatic equalization.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ ATTENTION! Make sure that the unit's maximum input power (reported on the data label) is available from your power supply, and verify that the unit's operating voltage is correct. Allow adequate air circulation to prevent internal heat buildup.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ • For the threephase units (ES2403 – ES4800 – ES6000), the wires to be moved are the THREE that are connected to the AC contactors, marked with the letters “A”, “B” and “C”.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ 4. HOW TO USE THE CHARGER PROGRAMMATION OF THE FINISHING CHARGE TIME The programmabie finishing charge times are 2 to 12 hours in the MRG Charge Controller. The default value (factory programmed) is 3 hours.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ BATTERY CONNECTION – AUTOMATIC VOLTAGE CHECK AND AUTOSTART ATTENTION! EagleSmart chargers are programmed to do a complete cycle of charge automatically, however it's recommended to survey the operation of the charger when the battery remains connected to the charger for more than 12 hours.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ When the charge is complete, the charger switches off automatically, and the MRG front panel will give the message “COMPLETE”: OVERVOLTAGE PROTECTION If, during the charge, the voltage of the battery will increase above 2,80 V/cell, the charger will shut down automatically, and the MRG front panel will show the m
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ AUTOMATIC DATA SAVING If, during the charge or equalization, one or more black-outs of the AC input occur, the microprocessor automatically saves all the relevant informations about the state of the charge.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ MANUAL CHARGE TERMINATION While the charge is in progress, it's possible to turn off the charger by pressing the red button “STOP”. The MRG front panel will show the message “MANUAL STOP”. In this condition, it's safe to disconnect the battery.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ QUICK TEST FUNCTION CAUTION! Risk of electrical shock! The charger can be serviced by qualified personnel only. Before to open the cabinet, disconnect the charger from battery and AC main supply.
ES2400 – ES2403 – ES4800 - ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ ATTENTION! It's always necessary to keep the battery disconnected while moving the QuickTest jumper. When the jumper is set to position NORMAL, the MRG controller works normally. When the jumper is set to position TEST, the MRG controller performs the complete charge cycle in seconds, instead of minutes.
' % % $# ! $ $ $ % # !# $# " ! " ! # ) # ' % % & ' & & & '& ! ! ! ! $ ! ' $ % % % % (% $ $ $ ! $# $+,+.
! " ! ! - - - ! ! .
! " ! ! ! $%% $%% "! " # ! . # # . . # # .
ES2400 – ES2403 – ES4800 – ES6000 User's Manual ___________________________________________________________________________________________________________________________________________________ Bassi Bruno elettromeccanica & C. S.n.c. Via Mensa 3/2, 48020 S. Maria in Fabriago – Lugo (RA) Tel +39 0545 995008 Fax +39 0545 995006 info@batterychargers.