Programming instructions
17 
USERS (Continued) 
; 6 : 
6. Enable Total User Lockout Mode 
(This Function enabled through keypad only) 
7. Disable Total User Lockout Mode 
(This Function enabled through keypad only) 
; 7 : 
User Lockout Mode  
Prevents all User Codes (Except User 1 Code) from operating the lock. Note:  No other programming 
functions or schedules will re-enable Users. Users must
 be re-enabled with Function 7. 
Note: Does not change the User enable/disable status. Note: If the lock is currently in Passage Mode 
(door "unlocked") and Function 6 is programmed, the lock will remain in Passage Mode. 
 M 
5. User Enable with Timeout 
(Enter Timeout, XXX Hours) 
(This Function enabled through keypad only) 
; 5 ; [ _ _ _ _ ]  ; [ _ _ _ _ ] : 
     (User Number)    (XXX Hours) 
• With Function 5, User Numbers must be between 2-2000, hours must be between 1-999. 
• Function 5 can temporarily override a disabled User (disabled using Function 3 above). 
• Since this is a temporary feature, Function 5 can only be enabled using the keypad. 
• Example: Brian, User Number 1157, rarely works at the office, but when he does, enable him for his 8 hour work day by entering 
Program Mode and pressing: ; 5 ; 1157 ; 008 :. 
• NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more 
than 4 Timeout Functions. 
 2 
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again. 
NOTE: User Number 297 is used to reset Service Code Use. See "Terminology Used in 
this Manual" on page 7 for more information and examples regarding special Users 297-300. 
; 9 : 
9. Enable User 300 (Service Code) 
 2  2 
; 1 0 ; 0 0 0 : 
10. Erase All Users Except the Master Code (User 1) 
(This Function enabled through keypad only) 
Erases all User Codes except the Master Code (User 1). 
• Function 10 can only be performed using the keypad. 
 M 
11. Reserved 
3. Disable User  
; 3 ; [ _ _ _ _ ] : 
(User Number) 
4. Enable User  
; 4 ; [ _ _ _ _ ] : 
(User Number) 
User Enable/Disable (By User Number) 
• User Number must be between 2 and 2000. 
NOTE: Will Enable/Disable Users even if the User is associated with an enabled Group. Use Feature 3 to disable a specific User 
Number and their associated User Code. If the disabled User Code is entered, the lock will flash 1 Green and 4 Red Flashes 
(with 1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3. 
 2 
8. Reserved 
Programming Functions (cont'd) 