Programming instructions
25 
; 6 7 ; [ _ _ ] : 
   (Event Number) 
67. Add System Features 
SYSTEM FEATURES 
68. Delete All Features added by Function 67.  
; 6 8 ; 0 0 0 : 
 4 
• System Options  
24.   One Time Access for Group 3 Users*** 
25.   Disable Sounder 
26.   5 sec. Delayed Entry * 
27.   15 sec. Delayed Entry * 
28.   45 sec. Delayed Entry * 
• Remote Input Functions 
29. Toggle Passage Mode. Remote Input toggles Passage 
Mode. 
30. Forced Unlock Follows Remote Input.** When Remote 
Input switch is closed, regardless of the current state of the 
lock, the lock unlocks for the duration of the Remote Input 
switch closure. 
32. Remote Input Disables Unit.**  Regardless of the current 
state, that state will remain unchanged (and keypad will be 
disabled) for the duration of Remote Input switch closure. 
34. Forced Lock Follows Remote Input ** When Remote Input 
switch is closed, regardless of the current state of the lock, the 
lock will lock for the duration of the Remote Input switch clo-
sure. 
* Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299). 
** Features 30, 32 & 34 should be used with External DC Power unless feature is used for short a duration and infrequently (sustained 
closure of remote input or relay will drain batteries). Scheduled events will not occur during sustained closure of remote input. 
Sustained closure of remote input may affect proper audit trail operation. . NOTE: Enter 
; 6 7 ; 0 0 0 : to 
delete all above features added by Function 67 (identical to Function 68). 
*** Feature 24, "One Time Access for Group 3 Users", allows the creation of multiple 'one time only' User Codes. When activated, an entry by 
a Group 3 User allows entry only once, then user becomes disabled. Note:  When the User Code is entered for the first time and access is 
granted, the Event Log will read "Entry" followed by "User Disabled". If the User Code is entered a second time, access will be denied, and 
the Event Log will read "User Denied Access". 
   To Enable the Feature: Enter Program Mode and enter the key sequence 
; 6 7 ; 2 4 :. 
   To assign the selected User Codes to Group 3: For example, to assign User Number 15 to Group 3, press: 
; 3 5 ; 1 
5 ; 3 :
. 
• PC Communication Functions 
33. Remote Input Puts Unit in PC Communication Mode 
Enter ; 6 8 ; 0 0 0 : to delete all Features added by Function 67. 
 4 
Programming Functions (cont'd) 