Lock Defaults for PDL6100 
Users added will default to a Group Association and a Programming Level ability as follows: 
USER TYPE  USER NUMBER 
GROUP DEFAULT 
ASSOCIATION 
MINIMUM PROGRAM 
LEVEL (See page 6) 
Master Code  1  -  M 
Installer Codes  2 & 3  none  4 
Manager Codes  4 - 6  none  3 
Supervisor Codes  7 - 9  none  2 
(Reserved)  10 - 11  none  -- 
Basic User Codes  12 - 50  none  none 
Basic User Codes Group 1  51 - 100  1  none 
Basic User Codes Group 2  101 - 150  2  none 
Basic User Codes Group 3  151 - 200  3  none 
Basic User Codes Group 4  201 - 250  4  none 
Basic User Codes  251 - 296  none  none 
Quick Enable User 300 Code  297  none  none 
(Reserved--see page 7)  298  none  none 
Guard Tour Code*  299  none  none 
Service Code  300  none  none 
Basic User Codes  301-5000  none  none 
*This code is a Non-Pass code and therefore does not allow passage through the door. 
1. New Master Code (User Number 1) 
; 1 ; [ _ _ _ _ _ _ ]  ; [ _ _ _ _ _ _ ] : 
 (New Master Code)   (Confirm New Master Code) 
2. Adding and Deleting User Codes and/or Proximity 
Cards (for User Numbers 2-5000)
; 2 ; [ _ _ _ _ ] ; [ _ _ _ _ _ _ ] : 
(User Number)   (User Code) 
• Master Code must be 6 digits-only. 
• Master Code is Keypad Code Access only. 
• Factory Default = 123456 
• See "Lock Design Overview" on page 5 for more information about Master Codes. 
 M 
USERS 
Programming Functions 
• User Number must be between 2 and 5000. 
• User Code must be 3-6 digits. 
• Each User Code can be thought of as a person.  As long as each person possesses their own 
unique User Code, you can control access to the lock by adding or deleting User Codes. See 
"Terminology Used in this Manual" on page 6 for more information. 
 3 
(Deleting Entire User) 
; 2 ; [ _ _ _ _ ] : [Beep Beep Beep] 
(Wait 10 seconds for 
beeping to end) 
(User Number) 
(Entering a Proximity Card) 
; 2 ; [ _ _ _ _ ] : [Beep Beep Beep] 
(Present card to reader 
within 10 seconds) 
(User Number) 
(Entering a "User Code" / "PIN No. Code" into the lock programming) 