22 
60. Number of Attempts Before Lockout 
61. Set the Attempts Lockout Time 
• Number of attempts before lockout must be 1-9 attempts. 
• The number of attempts is reduced by half every time the keypad is locked out without a 
successful code entry (default is 6 attempts). 
• The attempt count is reset each time a valid code is entered. 
• Lockout Time must be 1-60 seconds. 
How long the keypad is locked-out after a series of unsuccessful attempts 
(default is 18 seconds). 
 4 
 4 
LOCKOUT 
; 6 4 : 
64. Disable Remote Input 
• Wire a Normally Open Contact to Wires (White & White). Momentarily close switch to unlock door 
to allow person to pass through door. 
• Enter the functions below to Disable/Enable the Remote Input. 
NOTE: The Remote Input is enabled as part of the default program. 
Remote Input 
; 6 5 : 
65. Enable Remote Input 
; 6 6  ; [ _ _ ] : 
(Ambush Code) 
66. Ambush Code 
• Ambush code must be 2 digits. 
• An error will sound if the Ambush Code matches the 1st two digits of any User Code. 
See Function 67 for more information about the Ambush Function. 
 2 
 3 
REMOTE INPUT 
AMBUSH 
; 6 0 ; [ _ ] :  
(Number of Attempts) 
; 6 1 ; [ _ _ ] :  
(Lockout Time) 
62-63. Reserved 
Programming Functions (cont'd) 