Programming instructions
23 
; 6 7 ; [ _ _ ] : 
  (Event Number) 
67. Add System Features 
SYSTEM FEATURES 
68. Delete All Relay Features added by Function 67.  
; 6 8 ; 0 0 0 : 
• Relay Features (12-23. Reserved) 
Use Function 67 to program one or more lock events and the Relay will energize when the programmed event(s) listed below oc-
curs. For example, program ; 6 7 ; 3 : and when an attempted entry fails (such as a User who enters an 
incorrect or un-programmed User Code), the Relay will energize for 2 seconds. Note: For more information about the Remote In-
put, see page 10 (Wiring, Remote Input) and page 22 (Function 65).
1.  Remote Input switch closed and Function 65 Remote Input enabled. 
Because the Remote Input is enabled by factory default, the Relay will 
energize when the Remote Input switch is closed. 
9.  Lock Out. Relay energizes for 2 seconds when a Lock Out occurs (i.e. 
number of attempts is exceeded, see Function 60). 
2.  Remote Input switch closed and Function 64 Remote Input dis-
abled. If the Remote Input is disabled with Function 64, the Relay will 
energize when the Remote Input Switch is closed. 
10.    Ambush. Relay energizes for 2 seconds when Ambush is tripped. See 
Function 66, page 22. 
3.  Failed attempted entry. Relay energizes for 2 seconds when an at-
tempted User Code entry (or proximity card / keyfob) fails. 
11.    First Key Press. Relay energizes for 2 seconds at the first key press of 
any sequence. 
4.  Disabled User or Group. Relay energizes for 2 seconds when a dis-
abled User or disabled Group member enters a User Code (or proximity 
card / keyfob). 
5.  Follow Access Granted.  When a valid User Code is entered into the 
keypad and the lock unlocks, the Relay energizes for 2 seconds. Com-
pare with Event 31. 
6.  Group 1 User Code. Relay energizes for 2 seconds when a scheduled 
Group 1 User Code (or proximity card / keyfob) is entered. See 
Function 90, page 26. 
7.  Scheduled Lock Event. Relay energizes for 2 seconds when lock is 
locked by a Schedule. 
8.  Scheduled Unlock Event. Relay energizes for 2 seconds when lock is 
unlocked by a schedule 
31.    Follow Access Granted--No Time Limit.**  When a valid User Code is 
entered into the keypad and the lock unlocks, the Relay energizes for 
the same amount of time as the programmed Pass Time. (The Pass 
Time is the length of time the lock stays unlocked after a valid 
User Code is entered. See functions 52-54). Use this feature for 
remote monitoring or other activation as this feature works independ-
ently of all other relay options. Programming this feature will supersede 
all other programmed relay features. Subsequent relay feature pro-
gramming will not take effect while this feature is active. Before pro-
gramming any other relay features, press 
; 6 8 ; 0 
0 0 : to delete this feature. 
 4 
• System Options  
24.  One Time Access for Group 3 Users*** 
25.    Disable  Sounder 
26.  5 sec. Delayed Entry * 
27.  15 sec. Delayed Entry * 
28.  45 sec. Delayed Entry * 
• Remote Input Functions 
29.  Toggle Passage Mode. Remote Input toggles Passage Mode. 
30.  Forced Unlock Follows Remote Input.** When Remote Input switch 
is closed, regardless of the current state of the lock, the lock unlocks for 
the duration of the Remote Input switch closure. 
32.  Remote Input Disables Unit.**  Regardless of the current state, that 
state will remain unchanged (and keypad will be disabled) for the dura-
tion of Remote Input switch closure. 
34. Forced Lock Follows Remote Input ** When Remote Input switch is 
closed, regardless of the current state of the lock, the lock will lock for 
the duration of the Remote Input switch closure. 
* Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299, and any Emergency Command enabled User). 
** Features 30, 31 & 32 should be used with External DC Power unless feature is used for short a duration and infrequently (sustained closure of remote input or Relay 
will drain batteries, and scheduled events will not occur during sustained closure of remote input). Sustained closure of remote input may affect proper audit trail 
operation. NOTE: Enter ; 6 7 ; 0 0 0 : to delete all Relay Features added by Function 67 (identical to Function 68). 
*** Feature 24, "One Time Access for Group 3 Users", allows the creation of multiple 'one time only' User Codes.  When activated, an entry by a Group 3 User allows entry 
only once, then user becomes disabled. Note: When the User Code is entered for the first time and access is granted, the Event Log will read "Entry" followed by 
"User Disabled". If the User Code is entered a second time, access will be denied, and the Event Log will read "User Denied Access".  
To Enable the Feature:  Enter Program Mode and enter the key sequence ; 6 7 ; 2 4 :. To assign the selected User Codes to 
Group 3: For example, to assign User Number 15 to Group 3, press: ; 3 5 ; 1 5 ; 3 :. 
†
 Emergency Commands are disabled until a download from DL-Windows is performed. If a Function 67 or 68 (Clear Relay) is performed, Emergency Commands 
are turned off. 
Enter ; 6 8 ; 0 0 0 : to delete all Relay Features added by Function 67. 
 4 
Programming Functions (cont'd) 
Ambush Function 
1. Connect relay to a device able to properly monitor dry contacts for an Ambush condition. 
2. Program the Relay for Ambush Tripped using Program Function 67(10) above. 
3. Set the Ambush Code using Program Function 66. 
4. When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds. 
Notes: The Ambush Code defaults to 99. An error will sound if you try to program a new User Code starting with the Ambush Code. 
• Enable Emergency Commands
†
38.   Emergency Commands Enable (default = ON) 
39.   User Lockout on Emergency (default = ON) 