Programming instructions
29 
Groups and Scheduled Group 1 Examples (cont'd.) 
Functions 90/91: Use Function 90 and 91 (see page 26) to create a window of time where if any Group 1 User Code is entered within the 
programmed window, a Relay will be activated for 2 seconds. The Relay can be configured to disarm a burglary control panel. See page 26. 
1.  Enter Program Mode (if not in already). 
2.  Connect Relay to a burglar control panel with switch input for disarming. 
3.  Using Function 2, create User 4 with a User Code of "456789": 
Press ; 2 ; 4 ; 4 5 6 7 8 9 :. 
4.  Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35: 
Press ; 3 5 ; 4 ; 1 :. 
5.   Use Function 90 to set the time to open the window (8:30 A.M. all days of the week) allowing any Group 1 member to close the Relay for 2 
seconds. Note: Only 1 Relay closure will occur even if another member of Group 1 enters their User Code. Use Function 91 to set the 
time to close the window (10 A.M. for all days of the week): 
  Function 90 (Open Window Time) = 8:30 A.M.: Press ; 9 0 ; 0 ; 0 8 3 0 : 
  Function 91 (Close Window Time) = 10:00 A.M.: Press ; 9 1 ; 0 ; 1 0 0 0 : 
6.  Exit Program Mode (hold down any key for 3 seconds). 
The Relay will close, one time only, when a member of Group 1 enters their User Code between 8:30AM and 10:00AM. If a Group 1 User 
does not enter their User Code during the specified window, Functions 90/91 remain inactive 
• The alarm panel will have to be armed at night by the User or by an automatic schedule function of the alarm panel. 
Functions 92/93: Use Function 92 and 93 (see page 27) to create a window of time where if any Group 1 User Code is entered within the 
programmed window, Group 4 Users will be enabled. 
1.  Enter Program Mode (if not in already). 
2.  Using Function 2, create User 4 with a User Code of "456789": 
Press ; 2 ; 4 ; 4 5 6 7 8 9 :. 
3.  Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35: 
Press ; 3 5 ; 4 ; 1 :. 
4.  Using Function 17, disable Group 4. (Group 4 will need to be "disabled" before it can be "enabled" later). 
Press ; 1 7 :. 
5.  Use Function 92 to set the time to open the window (8:30 A.M. all days of the week) allowing any Group 1 member to enable Group 4. Use 
Function 93 to set the time to close the window (10:00 A.M. all days of the week). 
  Function 92 (Open Window Time) = 8:30 A.M.: Press ; 9 2 ; 0 ; 0 8 3 0 : 
  Function 93 (Close Window Time) = 10:00 A.M.: Press ; 9 3 ; 0 ; 1 0 0 0 : 
6.  Exit Program Mode (hold down any key for 3 seconds). 
The lock will now enable Group 4 User Codes if User 4 (or any Group 1 member) enters their User Code between 8:30 A.M. and 10 A.M. 
If no Group 1 member arrives to enter their User Code between 8:30 A.M. and 10 A.M., Group 4 User Codes will not be enabled and will 
remain disabled all day. 
• The device will have to be manually locked each night by entering the following command using Function 82: 
; 4 6 : 
• The device can also be programmed to automatically disable Group 4 members each night at 5 P.M. by using Function 82: 
; 8 2 ; 0 ; 1 7 0 0 : 
• Test the device by creating User 222 (with User Code 466466) and adding User 222 to Group 4: 
; 2 ; 2 2 2 ; 4 6 6 4 6 6 : 
; 3 5 ; 2 2 2 ; 4 : 