Programming instructions
27 
To Disarm a Burglary Control Panel 
90. Relay Activation 
(Open Time Window)
; 9 0  ; [ _ ] ; [ _ _ _ _ ] : 
        (Day)     (Time) 
Functions 90 and 91 allow you to set up a window of time where if any Group 1 User Code is entered within this window, 
the relay will be activated for 2 seconds. This relay is for use with a Control Panel that has a key switch disarm option. For 
additional information, see Group 1 Activated Features on page 29. 
• Also program Relay Function 6 using Function 67 (; 6 7 ; 6 :). 
• For day  enter: 1 for Sunday
, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 
8 for Monday to Friday
, 9 for Saturday and Sunday, and 0 for all days of week. 
• Enter time of day in 24 hour format (for example, for 2:15 PM, enter 14:15). 
Scheduled Relay Activation (Group 1 Activated) 
; 9 1  ; [ _ ]  ; [ _ _ _ _ ] : 
         (Day)   (Time) 
91. Relay Activation 
(Close Time Window)
SCHEDULES GROUP 1 ACTIVATED 
 3 
Bu rg l a r y
Control
Pa n e l
Re l a y
Output
Sw i t c h
Inp ut
Ext e r n a l
Re l a y
Arm ed
Lu g
Po w e r
Alarm Panel with Switched Input for Toggled Arm/Disarm 
NOTES 
1.  Group 1 Disarms a Burglary Control 
Panel will always disarm an alarm 
system. Arming should be performed 
by other means (such as Alarm Panel 
Keypad/Schedule). 
2.  Use a qualified electrical/alarm 
specialist to review your current alarm 
system and add additional components 
as needed (such as a relay, wire, 
resistors, connectors and/or diodes) and 
re-program the operation of your alarm 
system as needed. 
Bu rg l a r y
Control
Pa n e l
Re l a y
Output
Sw i t c h
Inp ut
Alarm Panel with Switched Input for Disarming 
Programming Functions (cont'd) 