A Top Safety and Protection Solution Worldwide! Table of Contents 1. Brief introduction -----------------------------------2 2. Safety Directions ------------------------------------2 3. Standard Packing list ------------------------------3 4. Physical Layout -------------------------------------3 5. Features -----------------------------------------------6 6. Settings -----------------------------------------------8 7. Operating Instructions --------------------------18 8.
A Top Safety and Protection Solution Worldwide! 1. Brief introduction The GSM Alarm System is a new security protection solution specially designed for your home, office and other applications. It’s based on Wireless GSM communication network, an integrated Lcd menu display and computer technology. When any sensor is activated, it will call & send an SMS to the owner’s telephone immediately. The GSM Alarm System has a user friendly design and all operations & settings are visual and intuitive.
A Top Safety and Protection Solution Worldwide! Use Qualified Maintenance Service Maintenance can be carried out only by a qualified maintainer. Waterproofness The product is not waterproof. Please install it in dry places and keep it dry. 3.
A Top Safety and Protection Solution Worldwide! Interface 1 Description Power External Power Connector, Connect to 2A@12V DC power Siren through AC/DC Adaptor. Will start for 60seconds when alarm is triggered. The siren GSM ANT or strobe siren should be <12V DC. Connect the GSM ANT, if the GSM signal is not strong, then please change the 3dB GSM ANT. Microphone One sensitive Microphone built inside. Interface 2 Description +12V +12VDC@1A power output for wired detectors.
A Top Safety and Protection Solution Worldwide! GND Ground point, connect to another wire of the wired Detector. IN4 Digital input 4, connect to one wire of the wired Detector. IN5 Digital input 5, connect to one wire of the wired Detector. GND Ground point, connect to another wire of the wired Detector. IN6 Digital input 6, connect to one wire of the wired Detector. IN7 Digital input7, connect to another wire of the wired Detector.
A Top Safety and Protection Solution Worldwide! 5. Features 5.
A Top Safety and Protection Solution Worldwide! 5.
A Top Safety and Protection Solution Worldwide! 15) Supports internal speaker to the user to use as a two-way voice communication; 16) It is Compatible with PT2262 and PT2242 wireless IC; 17) Standby internal rechargeable battery which can last 18 hours; 18) Based on the GSM communication network and Operation Menu Display technology, the system can be applied to wide range situations. 6. Settings Tips! 1) Please insert the SIM Card first then install the GSM antenna and then power it on.
A Top Safety and Protection Solution Worldwide! Please note: if the income call is from the preset number (Includes SMS Alert number and Auto-dial numbers), then if answered before 6 tones, will create a two-way voice communication. After 6 tones, it will enter into a wiretap status. The user can listen in to the alarm’s surround sounds. Max. time is 10Minutes. If the income call is not from the preset alarm number, after 6 tones, if it hasn’t been answered, it will hang up.
A Top Safety and Protection Solution Worldwide! : : Alarm link output indicator, when alarmed, will turn on and last 4minutes, meaning the alarm link output relay is closing. : Separate output relay indicator, when the independent output relay is closed, the indicator will be on, when the independent output relay is opened, the indicator will be off. 6.1.
A Top Safety and Protection Solution Worldwide! SOS, Panic Button. 6.2 Main Menu In standby mode, press the 1. View 2. Setup 6.2.1 View 1. Alarm Records 2.Timers button, you will see the Menu. ---To check the settings and event records of the system ---To setup the system functions, requires password, the default password is 1234. ---To check the alarm records, up to 100 event records will be saved ---To check the Timer you have setup 4.SMS Phone No.
A Top Safety and Protection Solution Worldwide! 6.2.2 Setup 1. Add/Del RF Parts ---To add or remove wireless sensors or remote controls and edit their attributes 2.Wired Zones Set ---To setup Wired Zone parameters of the system 3.Basic Setting ---To setup basic parameters of the system 4. Advanced Setting ---To setup the advanced parameters of the system. 6.2.2.1 Add/Del RF Parts 1.Edit RF Zone 2.Edit Remote Ctrl 3.
A Top Safety and Protection Solution Worldwide! Auto-Dial Tel. Numbers for 3 times one by one, and Send SMS to the Pre-set SMS Alert Numbers. In the meantime it will drive the siren for 60seconds and close the link-Output relay for 4 minutes. 2) After you enter the menu, the attribute of the zone will be displayed in the LCD, if this zone has been assigned a wireless sensor, it will display “V”.
A Top Safety and Protection Solution Worldwide! 02 Intrusion from Living Room Normal 03 Intrusion from Bed Room 1 Normal 04 Intrusion from Bed Room 2 Normal 05 Intrusion from Bed Room 3 Normal 06 Intrusion from Front Balcony Normal 07 Intrusion from Behind Balcony Normal 08 Intrusion from 1F Window Normal 09 Intrusion from 2F Window Normal 10 Intrusion from Left Fence Normal 11 Intrusion from Right Fence 12 Medical Button Alarm 13 Gas Leakage Alarm Normal 24-Hour zones, Thi
A Top Safety and Protection Solution Worldwide! 1) The Nodes Type NC,NO,EOL should reference the wired input sensor type. The Default is NC and all the inputs are shorted with wires. If you want to contact the wired sensors, then please replace the short wires by wired sensors directly. Please remain the no-use input in short-circuit with wires. Please see 8.4 Install the Wired Sensors and Electricity equipments 2) Zones’ Attribute definition of the wired zone is the same as the wireless zone.
A Top Safety and Protection Solution Worldwide! 1.SMS Phone No. 2. Auto-dial Tel No. 3. Time & Date 4. Sound Alarm ---To setup the SMS Alert Number, must be cell phone numbers, total 3. ---To setup the Auto-dial telephone number, total is 5 numbers. ---To setup the time and date information. The Format is Month-Date-Year. Press Up/Down to setup each item, press * to move to next item. ---Switch on or off the siren when Alarm occurs. ---Setup the Report time gap, Range: 0~240 Hours.
A Top Safety and Protection Solution Worldwide! For example: In South Africa, the country code is 0027, please note, do not write +27. The user cell phone number is for example 082 123 4567 and has been assigned as a SMS Alert number, the SIM Card number in the panel is for example 082 321 7654. Problem 1: Alarm but the user hasn’t received the SMS Alert. Solution: Please add the country code when you setup the 082 123 4567 as SMS Alert number, using 0027821234567 instead of 0821234567.
A Top Safety and Protection Solution Worldwide! 1.Edit Timer 2. Watchdog Timer ---To setup the starting time to arm and the Ending time to disarm. ---To setup the starting and ending time to work. ---To setup the remote control operation report function. 4. GSM Jammer Alert ---To setup the GSM Jammer Alert function. 3. RCO Alert 5. Modify Password ---Modify the system password. 6. Default Set --- Restore the system settings to factory defaults.
A Top Safety and Protection Solution Worldwide! table. If the setup is successful, the system will return OK to confirm the operation. E.g.: Modify the first wireless zone name as Front Door Opened by Intruder! You should edit a SMS Content: 1234#M01# Front Door Opened by Intruder!# ,the 1234 is the password. Then send it to the SIM card Number. For Wired Zone Name, the format is: Password+#+Z+Zone Serial Number+#+New Zone Name+#. Characters for the zone name are 32.
A Top Safety and Protection Solution Worldwide! the siren will stop and you can listen in on the alarm area by phone. Press the button “ ” on the remote control, or press Disarm button on the Keyboard then input the password, the Control Unit disarms immediately. The ICON will be off. Under this status, any sensor triggered, the control unit will not alarm. Except if the sensor type is the 24-Hour Zones or Watchdog zone or SOS zone.
A Top Safety and Protection Solution Worldwide! xxxxBB Example “xxxx” stands for the password 1111BB (1-4 digits). Return SMS When the Password is 1111 System deactivated. 7.2.3 Switch On the independent output relay xxxxCC Example “xxxx” stands for the password 1111CC (1-4 digits). Return SMS When the Password is 1111 Output Relay Closed. 7.2.4 Switch OFF the independent output relay xxxxDD Example “xxxx” stands for the password 1111DD (1-4 digits).
A Top Safety and Protection Solution Worldwide! status. It is not the alarm link Output Relay Status. 8. Installation Before installing the control unit, sensors and sirens, please help to test the system firstly, including wireless sensor, power supply, GSM signal, etc. Please ensure the wireless sensors and electrical appliances are more than 3~5m from the mainframe. 8.1 Insert SIM into Control Unit and install the GSM ANT. In the backside of the control unit, please install the GSM SIM card.
A Top Safety and Protection Solution Worldwide! Wireless glass break sensor can also be used (see below) For a scrolling steel door, a special wireless scroll steel door magnetic sensor must be used due to interference of the wireless signal caused by the steel door. Installation: attach the larger half to the floor and attach (rivet or glue) the smaller half to the scroll steel door. An alarm is triggered when the halves are separated by more than 3 to 5.00 cm. Scroll Steel Door 8.
A Top Safety and Protection Solution Worldwide! Wireless curtain sensor, detection area illustration below: 8.4 Install the Wired Sensors and Electricity equipments Please see below wiring diagram, then fix the related wired sensors and the sensors connected to the related digital inputs. Tips! 1) Please setup the NC, NO, EOL type in the PC Programmer correctly; 2) If you setup the Nodes type as NC (Default), the no-use inputs must be short-circuited by wires and the sensor type must be NC.
A Top Safety and Protection Solution Worldwide! series with every input, if you don’t connect the sensor to the input, please connect a 2.2K resistor in series to instead. Moreover, only the digital detector, NC type, can be used in EOL mode. Please see the below diagram. 4) If you setup the input type as NO, then please keep the two points of the inputs free and the sensor type must be NO. Please see the below diagram. 5) The Unit built-in 240VAC@3A rated relay.
A Top Safety and Protection Solution Worldwide! 8.5 Install the Control Unit In order to avoid destruction of the control unit by intruders, please install it in a concealed location, convenient to the operator. If applicable, ensure that an uninterruptible AC power outlet is available near the Control Unit. First connect accessories to the Control Unit then the AC adapter. 8.6 Install Siren Connecting the Siren to the Control Unit and fix them in appropriate locations.
A Top Safety and Protection Solution Worldwide! Notice: 1. Some wireless sensors must be coded by manual as below 9.1 step; some wireless sensors don’t need manual coding, because it will use the learning code sensor. Follow step 9.1 for learning the code wireless sensor, it is the same as the PIR-100B and DM-100A. 2. Please remember to setup the PIR-100B to Test Mode while programming the host.
A Top Safety and Protection Solution Worldwide! Select the Zone number, press Ok, to finish press OK, select the Normal Type Or Stay Type, then following the instruction: 1.Turn On the Device, means trigger the RF sensor, the system will show a code, then press Enter Key on the keyboard. The system will ask you to repeat the operation, so please trigger RF sensor again, when you see the code, then press the Enter Button on the Keyboard, the system will display Saved OK.
A Top Safety and Protection Solution Worldwide! Rated Voltage: 9~12VDC 2A Standby current: 30-40mA Siren Output Voltage: 12VDC Working temperature: -10℃~+60℃; Storage temperature:-20℃~+60℃ Relative humidity: Work frequency: 10-90%, No condensation 900/1800 MHz or 850/900/1800/1900MHz Communication protocol: GSM PHASE 2/2+ (include data service) Wireless sensor receiving frequency: 433 MHz Wireless sensor permission quantity: 16Pcs Wired Zones/ Remote Control permission quantity: 8Pcs/5Pcs Effect
A Top Safety and Protection Solution Worldwide! 12. Maintenance 1) If the Control Unit works, but the remote control and other sensors fail, please check and change the battery. 2) If the remote control works, but the Control Unit fails to send SMS texts, switch the power of Control Unit off and switch it on after one minute. Test this system after another minute, or check that the settings are correct and the GSM signals are strong enough.
A Top Safety and Protection Solution Worldwide! short PT2262 IC, and Ohm of the PT2262 Wireless sensor; incorrect Value; 3) Please pull out the wireless sensor 3) Haven’t pulled out antenna; wireless antenna; 4) Please install the wireless sensors or 4) Electromagnetic alarm panel away electric appliances; interference; 5) Please contact your distributors or 5) The wireless receiver manufacturer to replace it in the panel with problem.