Troubleshooting guide

Release January, 2006 Rev 4.0 24
PLC AND ALLSTAR CONTROL PANEL JUMPER DEFAULT SETTINGS BY DOOR MODEL
CONTROL PANEL TERMINAL NUMBERS
JUMPER
FUNCTION
/FIELD DEVICE
BEING
BYPASSED
JUMPER
NUMBER
MODELS
230, 570,
670 W
ALLSTAR
LIMITS
MODELS
230, 570,
670 W
ALLSTAR
ENCODER
MODELS
230, 570,
670 W PLC
CONTROL
MODEL
RE-COIL-
AWAY
Crank/Hoist Jumper1Crank/Hoist
XC0, XC1 XC0, XC1 XC0, XC1
Thermal Jumper2
Disengagement/Inertial
Brake Jumper3 XC2, XC3 XC2, XC3 XC2, XC3 XC2, XC3
Panel E-Stop Jumper4
Field E-Stop1 Jumper5 XC4, XC5 XC4, XC5 XC4, XC5 XC4, XC5
Field E-Stop2 Jumper6 XC5, XC6 XC5, XC6 XC5, XC6 XC5, XC6
Spare1 Jumper7 XC6, XC7 XC6, XC7 XC6, XC7 XC6, XC7
Spare2 Jumper7B XC7, XR1 XC7, XR1 XC7, XR1 XC7, XR1
Rapid Reset Jumper8
XR1,
0VDC XR1, 24V+
XR1, 0VDC
XR1,
0VDC
Setup Button Jumper9 XR1, XR0 XR1, XR0
Open Slowdown Limit Jumper10 XC0, XL1 XXXX XC0, XL1 XC0, XL1
Close Slowdown Limit Jumper11 XC0, XL2 XXXX XC0, XL2 XC0, XL2
Photocell PC-11 Jumper12
Photocell PC-12 Jumper13 XP3, XP2 XP3, XP2 XP3, XP2 XP3, XP2
Pneumatic Reversing
Edge Jumper14 XP2, XP1
Electric Reversing Edge Jumper15
XP1, X5
ON PLC
XP1, X5
ON PLC
XP1, X5 ON
PLC
Interlock1 Jumper16 XR0, XQ2 XR0, XQ2 XR0, XQ2 XR0, XQ2
Interlock2 Jumper17 XQ2, XQ1 XQ2, XQ1 XQ2, XQ1 XQ2, XQ1
Reset Button Jumper18
Special Jumper19 XXXX XR0, XL4 XXXX XXXX
Defeat Close Timer Jumper20
Mid Height Limit1 Jumper21 XR0, XL4 XXXX XR0, XL4 XR0, XL4
Mid Height Limit2 Jumper22 XR0, XL5 XXXX XR0, XL5 XR0, XL5
Photocell PC-13 Jumper23 XR0, XP5 XR0, XP5 XR0, XP5 XR0, XP5
Photocell PC-14 Jumper24 XP5, XP4 XP5, XP4 XP5, XP4 XP5, XP4
INSTRUCTIONS FOR FIELD INSTALLER
The above list shows the factory supplied jumpers. The purpose of these jumpers is to
make quick startup of the door possible without having to begin with every field device
completely wired. As the controls are started up and verified, each field device required
can be added one at a time and checked.
When connecting a field device to the terminal strip, remove only the jumper that bridges
the two terminals used by the device. Do not remove adjacent jumpers that only connect
to one of the two terminals being used by the device.