Troubleshooting guide
Release January, 2006 Rev 4.0 7
5. Put the system in the setup mode by pressing the SETUP button.
6. Run the door to the halfway point using the JOG SWITCH. This time release the JOG SWITCH
and allow the door to come to a complete stop. Press the RESET button to clear the setup mode.
7. Push the green actuator button. As the door cycles, observe the open and close limits. Reset limits as
necessary to obtain exact desired limits (repeat steps 1-6 as necessary).
Pressure Switch Adjustment
1. Bump the rubber safety edge with your hand and observe input X5 on the PLC. If LED does not flash
off or was never on, then adjust the pressure switch. Flip RUN/STOP switch on PLC to the STOP
position to ensure that door is unable to be actuated while performing this adjustment. Remove cover
of pressure switch enclosure (Figure 1. Rotate white plastic screw on pressure switch counter-
clockwise with small screwdriver until LED turns off. Rotate screw clockwise until input LED turns
on. Turn another 1/4 turn. Test safety edge and observe LED (it should turn off momentarily
whenever pressure is applied to safety edge).
2. Flip RUN/STOP switch back to RUN
Final Checks
1. Check photocells for proper operation. Breaking the photocell beam should reverse the door
2. Check all actuators for proper operation and not sticking open.
Figure 1