User's Manual

40/70 Issue 01 - April 2001 - Draft 03 3CC12425AAAA TQ BJA 01
46
For the mains connection, use only the connection cable supplied with the equipment.
Never use an extension cable for connecting the NT unit to the power source.
Stages (Figure 21 – The NT unit (85 – 264 V 47 – 63 Hz) )
1. Connect the X-Pol RT/NT connection cable.
2. To ground the NT unit in this way, carry out the procedures described in Chapter 3 – Installation of
the X-Pol RT’s A7390 Terminal Station. Use the lug and screw hardware supplied with the
equipment, ref. 7.
3. Check that the mains socket to which the NT is to be connected supplies voltage compliant with the
equipment characteristics and that it is fitted with an earth.
4. (ref. 5)
For NCAxxx: connect the NT connection cable to the NT connector and then to the mains.
For NGAxxx: connect the 48V cable to the HE15-3 connector, then to the 48V arrival.
5. Power-up the NT unit using the On/Off switch (ref. 6); the green "Power on" LED (ref. 3) lights up.
The red "Alarm" LED (ref. 4) lights up (searching for the carrier frequency) then flashes at different
rates according to the current phase:
slow flashing: automatic scanning over the frequencies,
fast flashing: frame recovery (authentication by the serial number) once the frequency is
found.
Malfunctions to the installation:
The A7390 is a reliable and easy-to-install system. By following the procedures described in the
documentation, no problems should occur. However, if these procedures have been poorly applied, here
is a list of the possible problems that may arise.
Manifestation of
the problem
Possible causes Solution
The red NT LED is
flashing slowly.
1 Errored NT declaration.
2 Poor connector contact.
3 Cable damaged or
severed.
4 Alignment problem.
5 Incorrect X-Pol RT set-
tings.
6 X-Pol RT breakdown.
7 NT breakdown.
1 Check NT declaration.
2 Check connectors. Secure loo-sely cabled
connectors.
3 Check installation wiring. Change damaged
cables.
4 and 5 Reconfigure and check antenna alignn-
ment.
6 Replace X-Pol RT.
The red NT LED is
flashing quickly.
1 Bad transmission.
2 Incorrect NT settings.
1 Delete and recreate the managed NT using
the 7390LT.
Check the allocation of the correct NT serial
number.
2 and 3 Reconfigure and check antenna alignn-
ment.
4 Replace X-Pol RT.
The red NT LED
rest lit uninterrup-
ted
1 Check the NT supply
voltage
2 NT breakdown.
Try a swith off/switch on, and if the LED remains
red, replace NT.
a