User's Manual

3CC12425AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 03 47/70
48
5 Operation and maintenance
5.1 7390 system supervision
The system operator receives the alarms sent by the network equipment. With the aid of the the 7390LT
software applications, the operator can view and analyze the alarms and trigger the appropriate
operations (see specific procedures below).
On detection of a fault, the operator analyzes alarms and starts the suitable maintenance actions.
5.2 Preventive maintenance
This maintenance is carried out, either during a corrective maintenance inspection, or during a periodic
inspection, on all station equipment. It consists in inspecting the units and their interconnections
(connectors, cables, sockets, etc.) and ensuring that the environment of the Indoor Units (NTs and RTs)
complies with installation requirements (see § 3 – Installation of the X-Pol RT’s A7390 Terminal Station).
It is essential to check connectors and splitters state with earthing.
In case of doubt, the suspect parts should be checked, taking all precautions to avoid interrupting link
data transmission.
5.3 Corrective maintenance
Corrective maintenance is carried out with the use of the programs of the 7390LT software.
To use the alarms refer to section "Alarms" of the Base Station User Manual 3CC 12426 Axxx.
5.4 Changing a faulty NT unit
Make sure that the network manager has deleted the NT to be replaced beforehand and declared the
new one, using the 7390LT software (see the Base Station User Manual 3CC 12426 Axxx).
Stages
1. Turn off NT unit power.
2. Disconnect the mains cable connecting the NT unit to the power source.
3. Disconnect all cables connected to the NT unit to be changed.
4. Change NT unit after checking that the characteristics coincide (number of inputs, impedance, etc.).
5. Reconnect NT unit cables.
6. Connect the NT power cable to the mains supply.
7. Power up NT unit.
8. Wait for "Power on" LED to light up.
9. Wait for flashing of "Alarm" LED. The NT unit is in operation once the LED is extinguished.
10. Make NT replace operation in the 7390LT software application (see section NT replace of the Base
Station User Manual 3CC 12426 Axxx)
DO NOT OPEN THE EQUIPMENT UNDER ANY CIRCUMSTANCE