User's Manual

3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 269/346
278
Communi-
cation Sub-
system
Failure
Comm_loss The connection (for manage-
ment link set-up) between the
active ANT board and the
"Board" element (redundant
ANT; TNT, AMD, IBS, CPL, coo-
ling unit, power supply unit) is
not set up or is lost.
When the alarm object is an NT,
it may mean a durable loss of
radio link.
Internal NE actions: reset
(automatic or controlled) of the
"Board" element if the board is a
TNT or AMD board or an NT.
No impact if the Board is an IBS
or X-Pol RBS board: these two
elements can continue to
function without their
management link.
The setup or re-establishment of
the connection requires the
complete (re)configuration of
this element. This procedure of
(re)confguration is automatic
and internal to the BS (as long
as all the element configu-ration
parameters are valid).
Operator action: no action.
Type mis-
match
Board_type_er
ror
1. Alarm on TNT board.
Alarm on TNT board after
changing a board (replacement
of board by another type of
board).
2. Alarm on NT board.
Alarm on NT unit after changing
a board (replacement of a unit by
another type of NT).
3. Alarm on CPL board.
Alarm on CPL board after
changing the board
(replacement of a board by
another type of board).
4. Alarm on ANT board.
Alarm on ANT board after
changing a board (replacement
of a board by another type of
board).
Internal NE actions: the "cross-
connections" are not in service.
Operator actions:
1. Change the board (see § 6.5 –
).
2. Change the board or suppress
the NT and recreate it.
3. Check type of the ANT and
CPL boards.
Change the ANT or CPL board
(see § 6.5).
4. Check the type of the ANT
board and change the board
(see § 6.5).
Probable
cause
Alarm name Definition Actions