7.3.3.4 Changing the capacity of an IP cross-connection
7.3.4 Change of power level (X-Pol RBS)
Order
number
of steps
Designation Comments
Refer to
screens or
paragraphs
concerned
I Suppression of the
"cross- connec-
tion" concerned
To modify the contract affected to an IP link, the
cross-connection must be suppressed first.
6.2.15 –
II Creation of the new
IP link
- assign the same value to the other parameters
(especially Vpi and Vci) as those of the previous
"cross-connection".
- assign the new bit rate desired for transmission
and for reception
6.2.14.5 –
4.13.2.3 –
table
THE POWER OF AN X-POL RBS MUST NOT BE MODIFIED IF RTS ARE ALREADY
IMPLEMENTED, POINTING TO IT. IN THIS CASE, CONTACT THE RADIO PIANNER.
Order
number
of steps
Designation Comments
Refer to
screens or
paragraphs
concerned
I Modification of the
power
On the X-Pol RBS Details screen:
- modify the transmission power
- validate by clicking on the «Apply» button
- close the application
4.5.7 –
II Checking the
modification
In the Current Alarms List:
- check that there are no new alarms for the X-Pol
RBS
4.10.1.3 –
III Updating the
installation record
Note the new value of the X-Pol RBS transmission
power in the BS installation record.
A.1.2 –