Table 20: IF cable loss characteristics, types and connectors
Note: Measured at 2050 MHz.
Measured at 900 MHz.
2.8.2 Marking IF cables for identification
IF cables must be marked to indicate which X-Pol RBS Tx or X-Pol RBS Rx each cable connects to. It
is recommended that you use bands of electrical tape to identify each cable:
the tape color (blue, red, green or yellow) indicates the sector,
the number of colored bands of tape indicates the X-Pol RBS Tx or X-Pol RBS Rx number in the
sector,
a white band on either side of the colored bands indicates that the IF cable connects to a redun-
dant X-Pol RBS Tx or X-Pol RBS Rx.
Table 21 describes the electrical tape recommended for marking IF cables.
Cable type
Connector Loss (dB/100 m [dB/100 ft])
Rating
Type Loss (dB) Downstream (1) Upstream (2)
Indoor
Heliax FSJ1-50A F1PNM 0.05 29.03 (8.85) 18.59 (5.66) Indoor
Heliax FSJ2-50 F2PNM 0.05 19.99 (6.09) 12.65 (3.86) Indoor
Heliax FSJ4-50 BF4PNM 0.05 17.76 (5.39) 11.07 (3.38) Indoor
Heliax HL4-RP-50 H4PNM 0.08 12.22 (3.91) 8.24 (2.51) Indoor/plenum
Heliax HJ5-50 H5PNM 0.08 6.07 (1.88) 3.92 (1.19) Indoor/plenum
Times Microwave LMR-400 Ultra Flex TC-400-NMH 0.10 23.82 (7.26) 15.39 (4.69) Indoor
Times Microwave LMR-600-LLPL TC-600-NMH 0.10 13.09 (3.99) 8.45 (2.57) Plenum/outdoor
Times Microwave LMR-900-FR EZ-900-NMH 0.10 8.76 (2.67) 5.56 (1.69) Indoor
Outdoor
Heliax LDF2-50 L2PNM 0.05 16.98 (5.18) 10.88 (3.32) Outdoor
Heliax LDF4-50A L4PNM 0.05 11.48 (3.50) 7.23 (2.20) Outdoor
Heliax LDF5-50A L5PNM 0.05 6.56 (2.00) 4.04 (1.23) Outdoor
Heliax LDF6-50 L6PNM 0.05 4.83 (1.47) 2.98 (0.91) Outdoor
CommScope CR50-540-PE CR540NM 0.10 10.4 (4.16) 6.59 (2.01) Outdoor
CommScope CR50-1070-PE CR1070NM 0.10 5.90 (1.80) 3.61 (1.10) Outdoor
Times Microwave LMR-600-LLPL TC-600-NMH 0.10 13.09 (3.99) 8.45 (2.57) Plenum/outdoor