User manual
 The Switch Menu
Page 18-29
3. You change an outgoing frame type by entering its line number, an equal sign (=) and a 
frame type indicator (e, s, 2, or 3). The frame type indicators represent the following 
frames:
e  Ethernet II or Ethertype
s SNAP
2  802.2 or LLC
3 Ethernet 802.3 
For example, if you wanted to translate incoming IPX SNAP frames to LLC frame, then 
you would enter
6=2
4. When you are done changing translations, enter save to save all of your settings. If you 
enter quit, you will exit the trdef command without saving your changes.
♦ Important Note ♦
The IP Translation Options allow only SNAP (
s). The 
IPX translations allow only SNAP (s), and LLC (2) for all 
frame types. The Ethertype (e) and 802.3 translations 
are not allowed for Token Ring.
The 
trdef command will accept your input and will not 
return an error message if you try to change an IPX 
translation option to Ethertype or Ethernet 802.3. 
However, that does not mean that the IPX frames are 
being translated to Ethertype or 802.3. Regardless of 
what the trdef screen displays, switch software does not 
translate Token Ring frames to Ethertype or 802.3.