User manual
Obtaining Status and Statistical Information
Page 29-42
Information on the Ports for One WSX Board
To obtain status information on a single WSX board, you enter the frstatus command along 
with the slot number for the WSX board, as follows:
frstatus <slot>
where <slot> is the slot number where the WSX board is installed. For example, if you wanted 
to obtain status information for the board in slot 4, you would enter:
frstatus 4
This command displays a screen similar to the following:
Frame Relay Status for slot: 4
  Admin/  VCs 
  Oper  Intf  Speed Active/  Frames Frames Octets Octets
 PTStatus Type BPS Inactive In Out  In  Out
 == ====== ==== =======  ======== ====== ======= ======== =======
 1 UP/UP V35DTE 2048000 2/0 364 128 8962 2650
 2 DN/DN *NONE* 9600 0/0 0 0 0 0
 3 UP/DN 232DTE 56000 0/0 89 90 890 895
 4 UP/UP V35DTE 256000 19/1 9 21 124 245
Each row in the table corresponds to a port on the WSX you requested information on.
PT
The Port number on the 
WSX board for which statistics are displayed.
Admin/Oper Status, Int Type, Speed Bps, DLCI Active/Inactive
These columns are described in the section, Information on All Boards in a Switch on page 
29-38. Please refer to this section for detailed information.
Frames In
The total number of frames received on this port since the last time the switch was initialized.
Frames Out
The total number of frames sent on this port since the last time the switch was initialized.
Octets In
The total number of Octets, or bytes, received on this port since the last time the switch was 
initialized. This statistic includes the data and Frame Relay header fields, but does not include 
CRC or flag characters.
Octets Out
The total number of Octets, or bytes, sent on this port since the last time the switch was 
initialized. This statistic includes the data and Frame Relay header fields, but does not include 