User's Manual
Table Of Contents
- 7368 ISAM ONT G-120W-F Product Guide
- 1 Preface
- Table of contents
- List of figures
- List of tables
- 2 ETSI ONT safety guidelines
- 3 ETSI environmental and CRoHS guidelines
- 4 ANSI ONT safety guidelines
- 5 G-120W-F unit data sheet
- 5.1 G-120W-F part numbers and identification
- 5.2 G-120W-F general description
- 5.3 G-120W-F software and installation feature support
- 5.4 G-120W-F interfaces and interface capacity
- 5.5 G-120W-F LEDs
- 5.6 G-120W-F detailed specifications
- 5.7 G-120W-F GEM ports and T-CONTs
- 5.8 G-120W-F performance monitoring statistics
- 5.9 G-120W-F functional blocks
- 5.10 G-120W-F standards compliance
- 5.11 G-120W-F special considerations
- 6 Install a G-120W-F indoor ONT
- 7 Replace a G-120W-F indoor ONT
- 8 Configure a G-120W-F indoor ONT
- 9 ONT configuration file over OMCI
- Customer document and product support
7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT
Issue: 01 3FE-46922-AAAA-TCZZA 141
2 Click Refresh to update the displayed information.
3 STOP. This procedure is complete.
Procedure 52 Optics module status retrieval
1 Select Status > Optics Module Status from the top-level menu in the SFU GPON Home
Gateway window, as shown in Figure 70.
Figure 70 Optics module status window
Table 49 describes the fields in the Optics module status window.
Table 49 Optics module status parameters
Field Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
Optics Module Temperature (ONT ANI-ONT-Side
Optical Measurements)
Optics module temperature, measured in C
Rx Optics Signal Level at 1490 nm (ONT
ANI-ONT-Side Optical Measurements)
Received optics signal level at 1490 nm, measured
in dBm
Tx Optics Signal Level at 1310 nm (ONT
ANI-ONT-Side Optical Measurements)
Transmitted optics signal level at 1310 nm,
measured in dBm
(1 of 2)
R05.06.01 | June 2017 | Edition 01