User's Manual
Table Of Contents
- G-240W-A Product Guide
- Preface
- ETSI ONT safety guidelines
- ETSI environmental and CRoHS guidelines
- ANSI ONT safety guidelines
- Contents
- List of figures
- List of tables
- 1 — G-240W-A unit data sheet
- 1.1 G-240W-A part numbers and identification
- 1.2 G-240W-A general description
- 1.3 G-240W-A software and installation feature support
- 1.4 G-240W-A interfaces and interface capacity
- 1.5 G-240W-A LEDs
- 1.6 G-240W-A detailed specifications
- 1.7 G-240W-A GEM ports and T-CONTs
- 1.8 G-240W-A performance monitoring statistics
- 1.9 G-240W-A functional blocks
- 1.10 G-240W-A standards compliance
- 1.11 G-240W-A special considerations
- 2 — Install a G-240W-A indoor ONT
- 3 — Replace a G-240W-A indoor ONT
- 4 — Configure a G-240W-A indoor ONT
- 4.1 General
- 4.2 HGU mode GUI configuration
- Login
- Procedure 4-1 Login to web-based GUI
- Device and connection status
- Procedure 4-2 Device information retrieval
- Procedure 4-3 LAN status retrieval
- Procedure 4-4 WAN status retrieval
- Procedure 4-5 WAN status IPv6 retrieval
- Procedure 4-6 Home networking information retrieval
- Procedure 4-7 Optics module status retrieval
- Procedure 4-8 Voice information retrieval
- Network configuration
- Procedure 4-9 LAN networking configuration
- Procedure 4-10 LAN IPv6 networking configuration
- Procedure 4-11 WAN networking configuration
- Procedure 4-12 WiFi networking configuration
- Procedure 4-13 Routing configuration
- Procedure 4-14 DNS configuration
- Procedure 4-15 TR-069 configuration
- Security configuration
- Procedure 4-16 Firewall configuration
- Procedure 4-17 MAC filter configuration
- Procedure 4-18 IP filter configuration
- Procedure 4-19 URL filter configuration
- Procedure 4-20 DMZ and ALG configuration
- Application configuration
- Procedure 4-21 Port forwarding configuration
- Procedure 4-22 DDNS configuration
- Procedure 4-23 NTP configuration
- Procedure 4-24 USB storage configuration
- Procedure 4-25 UPnP and DLNA configuration
- Maintenance
- Procedure 4-26 Password configuration
- Procedure 4-27 LOID configuration
- Procedure 4-28 SLID configuration
- Procedure 4-29 Device management
- Procedure 4-30 Backup and restore
- Procedure 4-31 Upgrade firmware
- Procedure 4-32 Reboot ONT
- Procedure 4-33 Restore factory defaults
- Procedure 4-34 Diagnose connections
- Procedure 4-35 View log files
- RG troubleshooting counters
- Procedure 4-36 Retrieve Residential Gateway (RG) troubleshooting counters
- 4.3 SFU mode GUI configuration
- 4.4 Operator ID
- 5 — ONT configuration file over OMCI
ANSI ONT safety guidelines
Alcatel-Lucent 7368 ISAM ONT xxxi
Edition 02
G-240W-A Product Guide
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• Use only cables approved by the relevant national electrical code.
• Use cables suitable for outdoor use for outdoor installation of ONTs.
• The ONTs have been evaluated for use with external POTS wiring without
primary protection that may not exceed 140 ft (43 m) in reach. However, the
power cable must not exceed 100 ft (31 m).
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of NEC
article 250 or local electrical codes.
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
Alcatel-Lucent recommends that you prepare the site before you install the ONT
equipment. In addition, you must control relative humidity, use static dissipating
material for furniture or flooring, and restrict the use of air conditioning.
Environmental requirements
See the ONT technical specification documentation for temperature ranges for
ONTs.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid condensation caused by rapid changes
in temperature and humidity, Alcatel-Lucent recommends:
• The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
• If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
• When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
Caution — This equipment is ESD sensitive. Proper ESD protections
should be used when entering the TELCO Access portion of the ONT.
R05.02.01 | October 2015 | 3FE-45360-AAAA-TCZZA | Edition 02