Site requirements for floor stand installations
Overview
This topic describes site requirements for cabinet installation on a floor, such as the
location and drilling of anchor holes for the floor stand.
Anchor hole specifications for Floor Stand
The following table provides anchoring specifications for floor stands installed in seismic
zones 0 through 4.
Seismic
zone(s)
Anchor type Number of
holes
Hole size
mm (inches)
Hole depth
mm (inches)
Torque Nm
(lbf in)
0, 1, 2 1/2inch Dia
drop-in
416mm
(5/8 in.)
50 mm
(2 in.)
24 (212)
3, 4 M12 x 125 mm 4 18 mm
(11/16 in.)
100 mm
(4 in.)
79 (700)
Basic site preparation requirements and footprints for
RRHs
Site requirements for RRHs
Site requirements for floor stand installations
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-16