Pole mount grounding
Each RRH cabinet must be grounded.
Each RRH cabinet must be grounded as follows:
At the top of the cabinet
At the left or right side of the cabinet.
The figure below shows how 2 AWG ground cable can be routed, along the pole, from the
RRH to the ground rod.
Important! For antenna sharing/daisy chain installations (two RRHs per sector), a
grounding bus bar must be installed within 6 feet of the RRHs, to ground the antenna
sharing surge protector.
35 mm
(2 AWG)
2
2 AWG to 2 AWG
To grounding
electrode/
ground rod
35 mm
(2 AWG)
2
35 mm
(2 AWG)
2
2 AWG to 2 AWG
Ground
bus bar
#6 AWG
ground cable
See Important! Note
Surge protector for
antenna sharing
6ftmax
distance
Grounding and lightning protection requirements for RRHs Grounding examples - Remote Radio Head
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................