Anchoring requirements
Overview
Cabinet anchoring must meet all requirements of the local codes, taking into
consideration the seismic zone of the installation site.
Anchor specifications
Use the following table to determine the type of anchor to use, and the hole size and depth
required for the anchor hole.
Equipment Seismic
Zone
Anchor Type Number of
Anchors
Required
Hole Size/Depth Anchor set
before or
after unit
placement?
9927
Distributed
Base Station
Outdoor
Cabinet
0, 1, 2 1/2" drop-in
anchor
4 16 mm (5/8 inch) bit /50
mm (2 inches) deep
Before
3, 4 12 mm
expansion stud
anchor
4 18 mm (11/16 inch) bit
/101 mm (4 inches)
minimum deep
1
After
60ECv2
battery cabinet
0, 1, 2 1/2 inch
drop-in anchor
4 16 mm bit (5/8 inch) /50
mm (2 inches) deep
Before
3, 4 12 mm
expansion stud
anchor
4 18 mm (11/16 inch) bit /
minimum 101 mm (4
inches) deep
1
After
Notes:
1. If a 101 mm (4 inch) hole depth cannot be attained for a 12 mm expansion stud anchor, a 76 mm (3 inch)
hole depth can be used. To make the anchor fit the shorter depth, a spacer may be removed from the anchor
assembly and 25 mm (1 inch) may be cut from the end of the threaded rod prior to setting the anchor.
Basic site preparation requirements and footprints for 9927
Distributed Base Station outdoor cabinet
Site requirements for 9927 Distributed Base Station
Outdoor cabinet